Connections & Installation; Multi-Drop Communication System - JVC LWT0254-001B-H Instructions Manual

Dome type camera
Table of Contents

Advertisement

Connections & Installation

Multi-Drop Communication System

A system that employs the RM-P2580 as the controller.
The following figure shows a system that can accommodate up to eight cameras. (100 positions can be preset per camera.)
Camera 1
Control signal cable
Coaxial cable
TK-C625
MACHINE ID: 01
Switch 8: OFF
(RX TERM)
Camera 2
TK-C625
MACHINE ID: 02
Switch 8: OFF
(RX TERM)
Camera 8
TK-C625
MACHINE ID: 08
Switch 8: ON
(RX TERM)
Remote control unit
Cable Connections (A pg. 16)
(Terminal side of Ceiling Mount)
Control signal cable
Coaxial cable
Power cable
Connection of the control signal cable
(A twisted pair cable is recommended.)
Camera 1
TX +
CONTROL
TX -
RX +
terminals
RX -
Camera 2
TX +
TX -
CONTROL
RX +
terminals
RX -
Camera 3
TX +
TX -
CONTROL
RX +
terminals
RX -
AC 24 V power
supply
A CAUTIONS
AC 24 V power
supply
A CAUTIONS
AC 24 V power
supply
A CAUTIONS
TO CAMERA
POWER
OFF
ON
RM-P2580
AC
INPUT
To the TO CAMERA terminal of
the RM-P2580 and to the next
camera
To the CAMERA INPUT terminal
of the RM-P2580
To AC 24V power supply
Listed class 2 input only
RX +
RM-P2580
RX -
terminals
TX +
TX -
Each terminal on the camera and
the RM-P2580 is marked
,
or
. In order to facilitate
understanding and to avoid
connection mistakes, it is
recommended to connect the
terminals carrying the same marks.
Observe the following points when connecting
components together:
●Turn all the components off before proceeding.
●Read the instruction manuals of all components before
proceeding.
●For the types and lengths of connection cables, see
Cable Connections (A pg. 16).
●Do not connect the control signal cables in a loop.
CAUTIONS
●The AC 24 V power supply must be isolated from the
primary line. (ISOLATED POWER ONLY)
●In order to prevent an excessive current flow through
the power supply wire or camera due to a short circuit,
a fuse must be installed in the power supply line.
TO CAMERA
DATA I / O
UNIT
CAMERA
RX+ RX- TX+ TX-
COM
1
2
3
4
5
6
7
8
COM 9/1 10/2 11/3 12/4 13/5 14/6 15/7 16/8 COM
AUTO
ALARM
COM
SW
VIDEO INPUT
1
2
3
4
5
6
1 2
3
4
5 6
7
8
1
2
3
4
5
6
ON
VIDEO OUTPUT
MONITOR OUTPUT 1
Switch Settings (A pg. 13)
(Setting switches are on the side of the Ceiling Mount)
ON
1
2
3
4
5
6
7
8
Switch 1 : Invalid (Set to OFF)
Switch 2 : Invalid (Set to OFF)
Switch 3 : Invalid (Set to OFF)
Switch 4 : ON
Switch 5 : OFF
Switch 7 : Invalid (Set to OFF)
Switch 8 : Set to ON only for the
camera connected at the
end of the control signal
cable. Set to OFF for all
other cameras.
Camera 1 monitor display at power ON
,
,
<Procedures for Checking
Machine ID> (A pg. 14)
SERIAL-1
SERIAL-2
COM
7
8
MONITOR
MONITOR
OUTPUT
OUTPUT
1
2
7
8
Machine ID
Set to the Video Input number of
RM-P2580.
(Setting procedures A pg. 14)
>>
<<
INITIAL PROCESS
PAN
: - - I - -
TILT
: - - I - -
PROTOCOL
DUPLEX I D - 01
Duplex display
ID No. display
9
EN
Monitor

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-c625eTk-c625uTk-c625

Table of Contents