Camera Title/Alarm Screen - JVC LWT0254-001B-H Instructions Manual

Dome type camera
Table of Contents

Advertisement

Setting Up the Camera Using RM-P2580 (continued)
26
EN

CAMERA TITLE/ALARM Screen

Item
CAM. TITLE EDIT..
Use this to specify the title that is always displayed at the bottom left of the screen. Specify
up to a maximum of 16 characters. CAMERA TITLE Setup (A pg. 34)
AREA DISPLAY
Use this to perform area setting.
AREA DISPLAY Setup (TITLE) (A pg. 35)
AREA DISPLAY Setup (DIRECTION) (A pg. 36)
OFF
Not displayed.
TITLE
Equally divides the 360° panning range into 16 areas, and a title of up to 16 characters can
be specified for each area. The corresponding area title specified will be displayed upon
panning the camera manually. AREA DISPLAY Setup (TITLE) (A pg. 35)
DIR
Set N (North), which is the direction of the standard axis. When the camera is panned manually,
the 360° panning range will be equally divided into 8 areas, each indicated by N, NE, E, SE, S,
SW, W and NW respectively. AREA DISPLAY Setup (DIRECTION) (A pg. 36)
ALARM TITLE SIZE
Use this to set the size of the title during an alarm.
NORMAL: Same size as characters on the menu screen.
DOUBLE: Double the size, both vertically and horizontally, of the characters on the menu screen.
ALARM TITLE
This is a screen for setting the title during an alarm.
EDIT..
ALARM TITLE Setup (A pg. 37)
ALARM INPUT..
These items are used to perform setting related to the alarm input terminals.
MODE
For selecting the mode of the camera for which images are to be output when there is an alarm input.
OFF
HOME
POS1-99 : Output images at a selected preset position during an alarm input.
● Setting the B&W MODE (A pg. 27) item to ALARM IN switches the mode to the B&W mode and
setting cannot be changed.
POLARITY
For setting the polarity of alarm input signals.
MAKE
BREAK : Input alarm signals when the contact between each alarm input terminal and the
● This item will be displayed as "- - -" when the MODE item is set to OFF and setting is not possible.
TIME
Use this to set the duration of alarm signal output as well as alarm title display when there is
an alarm.
[Set values: 5 s, 6 s, 7 s, 8 s, 9 s, 10 s, 15 s, 20 s, 30 s, 60 s]
CAUTION
For RM-P2580 systems, this setting is disabled. Set using the Alarm Time item of RM-
P2580. (A RM-P2580 INSTRUCTIONS )
● This item will be displayed as "- - -" when the MODE item is set to OFF or when the B&W MODE
(A pg. 27) item is set to ALARM IN . In both cases, setting will not be possible.
PRIORITY
Sets whether or not manual operation is accepted in case an alarm input is recognized
during manual operation of the camera.
ALARM : Manual operation is not accepted when there is an alarm input.
MANUAL : Manual operation is accepted even when there is an alarm input.
CAUTION
This item is invalid with a system using the RM-P2580. With this system, the ALARM
input will permanently override manual operation.
ALARM OUTPUT..
Use this to perform setting related to the alarm output terminal.
OFF
ALARM
B&W
PRESET
AUX 1 to AUX 3 : Output alarm signals when there is an auxiliary input.
Function/Set Value
: Does not output images even when there is an alarm input.
: Output images at the home position during an alarm input.
: Input alarm signals when the contact between each alarm input terminal and the
GND terminal changes from open to closed.
GND terminal changes from closed to open.
(Priority given to alarm)
(Priority given to manual)
: Do not output alarm.
: Output alarm signals when there is an alarm input.
: Output alarm signals when the camera switches to the B&W mode.
: Output alarm signals when the camera moves to a preset position.
Initial
Value
^
OFF
^
DOUBLE
^
OFF
MAKE
5 s
ALARM
OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-c625eTk-c625uTk-c625

Table of Contents