Correct Baffle & Blanket Placement - Quadra-Fire 4100I-GD-B User Manual

4100-i act wood insert
Hide thumbs Also See for 4100I-GD-B:
Table of Contents

Advertisement

4100-I ACT Wood Insert
CORRECT BAFFLE & CERAMIC BLANKET PLACEMENT
WARNING
Fire Risk
Firebox damage due to improper baffle place-
ment is not covered by warranty. Operate the
wood burning appliance with the baffle in the
correct position only.
Not doing so could result in:
• Reduced efficiency
• Overheating the chimney
• Overheating the rear of the firebox
• Poor performance
Ensure correct baffle placement and replace baffle
components if damaged or missing.
The baffle boards are FRAGILE. Use extreme caution
when loading firewood to prevent:
• Cracking, breaking or damaging the baffle boards
DO NOT operate the stove without baffle boards
CORRECT POSITION
Ceramic Blanket
Baffle Board
Ceramic Blanket and Baffle Board MUST
be in contact with the back of the fire-
box and even with each other in the front.
Figure 24.1
Page 24
CAUTION
Back of Firebox
INCORRECT POSITIONS
Ceramic Blanket and Baffle Board are NOT in
contact with the back of the firebox.
Ceramic Blanket is NOT in contact with the
back of the firebox and NOT even with the
Baffle Board in the front.
Ceramic Blanket
Baffle Board
Ceramic Blanket is bunched up at the back
of the firebox and NOT even with the Baffle
Board in the front.
Figure 24.2
250-7201F
R
Back of Firebox
April 19, 2010

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4100i-nl-b4100-i act

Table of Contents