Quadra-Fire 41I-ACC Owner's Manual

Wood insert automatic combustion control (acc)
Hide thumbs Also See for 41I-ACC:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions on installation, operation, or service.
NOTICE: DO NOT DISCARD THIS MANUAL
41-I ACC WOOD INSERT
Automatic Combustion Control (ACC)
Model(s):
41I-ACC
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate
poisonous gases (i.e. carbon monoxide).
Installation and service of this
appliance should be performed by
quali ed personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.
1
Owner's Manual
Operation & Care
7045-909D
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
NOTE
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafi re.com
February 25, 2016

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 41I-ACC

  • Page 1 • Do not store or use gasoline or other fl am- Model(s): mable vapors and liquids in the vicinity of 41I-ACC this or any other appliance. • Do not overfi re - If heater or chimney con- nector glows, you are overfi ring. Overfi ring will void your warranty.
  • Page 2: Congratulations

    Hearth & Home Technologies welcomes you to our tradition old-fashioned when it comes to craftsmanship. Each unit of excellence! In choosing a Quadra-Fire appliance, you is meticulously fabricated and gold and nickel surfaces are have our assurance of commitment to quality, durability, and hand-fi...
  • Page 3: Table Of Contents

    41I-ACC Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
  • Page 4: Warranty

    41I-ACC C. Warranty Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
  • Page 5 41I-ACC WARRANTY CONDITIONS: ‡ 7KLV ZDUUDQW\ RQO\ FRYHUV ++7 DSSOLDQFHV WKDW DUH SXUFKDVHG WKURXJK DQ ++7 DXWKRUL]HG GHDOHU RU GLVWULEXWRU $ OLVW RI ++7 DXWKRUL]HG GHDOHUV LV DYDLODEOH RQ WKH ++7 EUDQGHG ZHEVLWHV ‡ 7KLV ZDUUDQW\ LV RQO\ YDOLG ZKLOH WKH ++7 DSSOLDQFH UHPDLQV DW WKH VLWH RI RULJLQDO LQVWDOODWLRQ ‡...
  • Page 6: Quick Start Guide

    41I-ACC D. Quick Start Guide Note: These are generic drawings and may not represent your specifi c model. 10 Pieces of Newspaper, 10-20 Pieces of Dry Kindling ITEMS NEEDED FOR FIRST FIRE: and a Few Pieces of Dry Split Wood.
  • Page 7: Listing And Code Approvals

    (8600) times the effi ciency. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. The Quadra-Fire 4100 Wood Insert (ACC) meets the U.S. For assistance or additional information, consult a qualifi ed Environmental Protection Agency’s crib wood emission limits installer, service agency or your dealer.
  • Page 8: Operating Instructions

    41I-ACC User Guide Operating Instructions WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass •...
  • Page 9: Fire Safety

    41I-ACC B. Fire Safety To provide reasonable fi re safety, the following should be given • Contact your local chimney professional and have your serious consideration: stove and stove pipe inspected for any damage. Install at least one smoke detector on each fl oor of your •...
  • Page 10: Burning Process

    fl ames. placed on the burning of wood for home heating. During this stage of burning: In order to improve the situation, we at Quadra-Fire have • The fl ames must be maintained and not allowed to go out developed cleaner-burning wood appliances that surpass ensure the cleanest possible fi...
  • Page 11: Automatic Combustion Control (Acc)

    41I-ACC G. Automatic Combustion Control (ACC) Typically, when you build a fi re, you open the air controls fully and monitor the fi re to prevent it from going into an overfi re situation and/or burning your wood up too quickly before you shut down the air controls to the desired burn rate.
  • Page 12: Burn Rates And Operating Effi Ciency

    41I-ACC 3. Burn Rate Air Control 4. Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr* • The air supply enters at the upper front of the fi rebox, • Raise the Burn Rate Air Control up to the bottom of the near the top of the glass door.
  • Page 13: Correct Baffl E & Blanket Placement

    41I-ACC J. Correct Baffl e & Blanket Placement INCORRECT POSITIONS WARNING Fire Risk Improper baffl e placement may cause: • Overheating of fi rebox • Overheating the chimney Baffl e must be placed properly (see instructions) Replace baffl e if damaged or missing.
  • Page 14: Building A Fire

    41I-ACC K. Building A Fire 10. When ready to reload, It is best to fully open both the Burn Rate Air and Start-up Air Controls before reloading. WARNING • This livens up the coal bed and reduces excessive emissions (opacity/smoke).
  • Page 15: Wood Fuel

    41I-ACC L. Wood Fuel WARNING Fire Risk. WARNING • Do NOT burn wet or green wood. • Store wood in dry location. Fire Risk. • Stack wood so both ends are exposed to air. • DO NOT BURN GARBAGE OR FLAMMABLE Wet, unseasoned wood can cause accumulation of creosote.
  • Page 16: Operating The Blower Control Box With Snap Disc

    41I-ACC M. Operating the Blower Control Box with Snap Disc 1. The blower will turn on/off automatically when set to AUTO. Figure 16.1. 2. When set to MANUAL, the fan will turn on/off only when you turn it on or off. This setting over-rides the internal snap disc.
  • Page 17: Clear Space

    41I-ACC Q. Opacity (Smoke) O. Clear Space Opacity is the measure of how cleanly your appliance is • Do NOT place combustible objects within 4 ft (1.2 m) of burning. the front of appliance. Figure 17.1. Opacity is measured in percent: •...
  • Page 18: Maintenance And Service

    41I-ACC Maintenance and Service When properly maintained, your fi replace will give you many years Creosote - Formation and Need for Removal of trouble-free service. Contact your dealer to answer questions • When wood is burned slowly, it produces tar and other...
  • Page 19: Glass Cleaning

    41I-ACC E. Glass Cleaning F. Inspect Firebrick • Frequency: As desired • Frequency: After each ash removal • By: Homeowner • By: Homeowner Replace the fi rebrick if they become crumbly and/or if there • Clean glass with a non-abrasive glass cleaner. Abrasive is a 1/4 inch (6.35mm) gap between the bricks.
  • Page 20: Quick Reference Maintenance Guide

    41I-ACC G. Quick Reference Maintenance Guide Start the fi rst inspection after the fi rst 2 months of use, or if performance changes, and adjust your schedule according- CAUTION! Allow the appliance to completely cool ly. Maintenance is required for safe operation and must be down before performing any cleaning or maintenance.
  • Page 21: Troubleshooting Guide

    41I-ACC Troubleshooting Guide With proper installation, operation, and maintenance your wood stove will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist you or a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken.
  • Page 22: Service Parts Replacement

    DO NOT OVER TIGHTEN - can cause glass to break. Replace the door on the appliance. Quadra-Fire appliances are equipped with ceramic super heat-resistant glass, which can only be broken by impact Snap Disc Blower Housing Assembly or misuse.
  • Page 23: Blower Replacement

    41I-ACC C. Blower Replacement CAUTION 1. Remove the 2 screws from the Blower Housing Assem- Shock Risk. bly using a 5/32 allen wrench. Figure 23.1. • Do NOT remove grounding prong from plug. • Plug directly into properly grounded 3 prong 2.
  • Page 24: Baffl E Removal

    41I-ACC D. Baffl e Removal E. Door Handle Assembly 1. Remove all ash from the fi rebox, and extinguish all hot embers before disposal into a metal container. CAUTION! Do not over tighten lock nut. The door handle 2. The baffl e board has 2 pieces. With the ceramic blanket needs to move smoothly.
  • Page 25: Tube Channel Assembly Replacement

    41I-ACC G. Tube Channel Assembly Replacement is off the threads. Drop the right side down, then slide the assembly back to right. Removing Tube Channel Assembly 5. The ceramic blanket and both baffl e boards can be removed at the same time you remove the tube channel 1.
  • Page 26: Reference Materials

    41I-ACC Reference Materials A. Service & Maintenance Log Date of Service Performed By Description of Service 7045-909D February 25, 2016...
  • Page 27: Service Parts & Accessories

    41I-ACC B. Service Parts & Accessories 41I-ACC-BK Service Parts Beginning Manufacturing Date: Sept 2011 Wood Insert Ending Manufacturing Date: Active Part number list on following page. 09/15 February 25, 2016 7045-909D...
  • Page 28 41I-ACC 41I-ACC-BK Service Parts Beginning Manufacturing Date: Sept 2011 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 29 41I-ACC 41I-ACC-BK Service Parts Beginning Manufacturing Date: Sept 2011 Ending Manufacturing Date: Active #10 Door Assembly w/Glass 10.1 10.2 10.3 10.4 10.7 10.5 10.6 IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 30 41I-ACC 41I-ACC-BK Service Parts Beginning Manufacturing Date: Sept 2011 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 31 41I-ACC February 25, 2016 7045-909D...
  • Page 32: Contact Information

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents