Adjusting Air Flow to Burner
1. Loosen air shutter lock screw.
2. Turn air shutter to left to get a
luminous yellow-tipped flame,
turn it back slowly to the right to
obtain a steady, soft blue flame.
3. After air shutter is adjusted for
proper flame, tighten air shutter
lock screw securely.
After the dryer has operated for
approximately three minutes,
exhaust air or exhaust pipe should
be warm.
A-14
7.7"
(19,6 cm)
4.0"
4.0"
(10,2 cm)
.4"
28"
(1,1 cm)
(71,1 cm)
*With leveling legs turned fully into base
SIDE VIEW
Closet
Door
2" (5,1 cm)
12"
0"
(30,5 cm)
(0 cm)
Min.
2" (5,1 cm)
Outer wall of
enclosure
15.4"
(39,1 cm)
2.8"
2.3"
(7 cm)
(6 cm)
26.9"
(68,3 cm)
FRONT VIEW
(Closet Door)
3" (7,6 cm)
Centered air
openings minimum
40 sq. in.
(260 sq. cm) each
3" (7,6 cm)
Air shutter
lockscrew
Appliance main
gas valve
6
16025315
Checking Burner Flame
To view the burner flame, remove the
lower front panel of the dryer.
WARNING
To prevent personal injury or
property damage, front panel
must be in place during normal
operation.
Close the loading door, start the
dryer in a heat setting (refer to User's
Guide) The dryer will start, ignitor will
glow red, and main burner will ignite.
IMPORTANT: If all air is not purged
out of gas line, gas ignitor may go
off before gas is ignited. If this
happens, after approximately two
minutes ignitor will again attempt
gas ignition.
After the dryer has operated for
approximately 5 minutes, observe
burner flame through lower front
panel. Adjust air shutter to obtain a
soft, uniform blue flame. (A lazy,
yellow tipped flame indicates lack of
air. A harsh, roaring, very blue flame
indicates too much air.)