CONNECT GAS
3
SUPPLY
L.P./Propane
DO NOT connect dryer to
L.P./Propane gas service without
converting the gas valve. An LPK1
Sales Accessory L.P./Propane Gas
Conversion Kit 649P3 must be
installed.
Test for Gas Leaks
After final gas con-
nection is made,
turn on manual gas
valve and test all
connections in gas supply piping for
gas leaks. Leak testing of the appli-
ance shall be conducted according
to the manufacturer's instructions.
1. Place soap suds on connections.
2. If bubbles appear, a leak is pre-
sent. Shut off gas supply valve.
3. Tighten joint if leak is at factory
fitting.
• If leak is not at factory fitting,
unscrew, apply more joint
compound, and tighten to cor-
rect leak.
4. Retest connection for leak after
tightening or adding joint
compound.
• Retest any connections that
were disturbed.
4
CONNECT
POWER CORD
TO ELECTRICITY
See Installation Requirements
section. Plug dryer into 3-prong
grounded outlet only.
©2006 Maytag Services
Connect gas supply to dryer using a
new stainless steel flexible connec-
tor or hard pipe (check local codes)
according to illustration. Test for
leaks and check burner flame after
gas supply is connected. See
Checking Burner Flame section on
back page.
• Dryer must be connected to type
of gas as shown on nameplate
located in the door recess.
Use new stainless steel flexible connector
only if allowed by local codes (use Design A.G.A. certified connector)
3/8" NPT gas
connection
Black iron pipe
Shorter than 20' (6,1 m) - use 3/8" pipe
Longer than 20' (6,1 m) - use 1/2" pipe
For proper operation at altitudes
above 2,500 feet
The natural gas valve spud orifice
size must be reduced to ensure
complete combustion. See table.
5
POSITION AND
LEVEL DRYER
Place dryer in position,
adjust all legs (4)
until dryer is level
side to side and
front to back.
3
16026315
• Use pipe joint compound insolu-
ble on LP (propane) Gas, or
Teflon tape, on all pipe threads.
• Purge air and sediment from gas
supply line before connecting it to
the dryer. Before tightening the
connection, purge remaining air
from gas line to dryer until odor of
gas is detected. This step is
required to prevent gas valve
contamination.
1/8" NPT pipe plug
(for checking inlet
gas pressure)
Install equipment
shut-off valve
within 6' (1,8 m)
of dryer.
Altitude
Ft. (M)
3000 (915)
6000 (1830)
8000 (2440)
9000 (2740)
10000 (3050)
Level
Dryer
Base
Leveling
Leg
Orfice
Part
Size #
Number
43
503778
44
58719
45
503779
46
503780
47
503781
A-11