Conversion To Alternate Fuel; Conversion Kit Instructions - Quadra-Fire GRAND BAY 40 GB40FS Installation, Operation, Venting And Maintenance Instructions

Gas freestanding stove
Table of Contents

Advertisement

Kit Contents:
(1) Pilot Line
(3) Burner Orifices
(1) Pilot assembly
(1) Conversion Sticker
(1) Lox-it Fitting
(1) HI/LO Valve Regulator with instructions
Directions:
1. Remove door, logs, burner tubes,
nuggets and rear log shelf.
2. Remove 4 screws from burner pan
and remove. See Figure A
3. Remove control panel cover.
See Figure B
4. Remove two screws on pilot tower
assembly and disengage assembly.
See Figure C
5. Use 7/16" wrench to disconnect
pilot line at valve.
Page 30
Grand Bay 40 Gas Freestanding

CONVERSION KIT INSTRUCTIONS

NG Part #842-1361 LP Part#842-1641
Tools Required:
3/8" socket and open end wrenches
7/16" socket and open end wrenches
10 mm open end wrench
TH20 torque screwdriver
Phillips screwdriver
Gas Leak Detector
Manometer
FIG. A
FIG. B
Pilot Tower
FIG. C
Pilot Line
January 2000