DOOR/HOPPER/FUEL LEVEL SENSOR TROUBLE-SHOOTING
Items to check:
IF YOU GET THE "DOOR OPEN" ICON:
*Check the front door. Make sure the latch is closed.
*Check the sensor mount & magnet.
*Check the connection to the control board.
*Replace the sensor if previous checks are good.
IF YOU GET THE "HOPPER OPEN" ICON:
*Check the hopper door. Make sure it is closed.
*Check the sensor mount & magnet.
*Check the connection to the control board.
*Replace the sensor if previous checks are good.
IF YOU GET THE "FUEL LOW" ICON:
*Check the fuel level in the hopper. Add fuel if low.
*Check the sensor mount. Reposition sensor if needed.
*Touch the sensor with your finger, if the yellow light
doesn't come on, replace the sensor.
9-30-2010
DOOR / HOPPER SENSOR (#7000-375)
FUEL LEVEL SENSOR (#7000-380)
PAGE 21
Wall Control Error Code
(DOOR OPEN)
(HOPPER OPEN)
(FUEL LOW)
7020-057D

Advertisement