Electrical Supply; Auger Engagement; Bin Control; Initial Start Up, Checks And Adjustment Instructions - Cornelius 500 Series Installation And Service Manual

Hide thumbs Also See for 500 Series:
Table of Contents

Advertisement

F. E
S
LECTRICAL
UPPLY
1. Power Access—is provided with a 7/8" dia. knockout hole in the rear panel. Route incoming power in conduit,
through rear panel to icemaker electrical control box. Make connections to wires provided in the control box
and ground lug/screw.
2. Fused Line—should be checked and sized according to electrical rating shown on unit nameplate.
G. A
E
UGER
NGAGEMENT
1. Be certain that auger is fully engaged to lower drive and extruding head is fully engaged into evaporator.
H. B
C
IN
ONTROL
1. Remove tape holding control to white ice chute and also remove control bracket mounting screw located in
base of unit behind electrical box. (Screw will be used later to fasten bin control bracket to base of unit).
2. Slide control and bracket down chute to base of unit. very carefully guide control and bracket through 1/2" hole
in front of ice chute. Use CAUTION to be sure control goes into bin, not between base of unit and bin top.
3. Check location of bin control, it should be directly under ice chute at a 45
mounting screw that was removed in Step 1 to secure bracket to base. See Figure 4.
I
S
U
NITIAL
TART
P
NOTE: Do not start unit before completing installation steps on pages 6 through 8.
Turn on water supply (if unit is water cooled turn water on to condenser also) turn on main power switch (located on
top of electrical box), and make the following system checks:
NOTE: If unit will not start be sure water reservoir is full. Low water safety control must be properly
adjusted to start and shut down unit. If water level drops below bottom of reservoir, unit must shut
down. Adjustment is made by moving magnet up or down.
Water Level—
If necessary adjust float by bending float arm up or down as needed, push float assembly down until
unit stops running. Release float and unit will restart. Keep water in reservoir at level line while unit is in operation. See
Figure 5.
Low Water Safety Control—Adjust magnet by bending magnet arm as needed to shut unit down if water level drops
below bottom of reservoir.
Bin Control—Place ice around probe, unit should shut down in one minute. Remove ice from around probe, unit
should start in two minutes.
NOTE: For altitudes over 1000 feet above sea level, adjust range screw (behind end cover). Half
turn max. raises setting 4
© 2002-2014, Cornelius Inc.
Figure 4. Bin Control
, C
A
HECKS AND
DJUSTMENT
°
F approx.
Continuous Flow Icemaker Installation and Service Manual
°
angle. With control in place use
I
NSTRUCTIONS
- 8 -
Publication Number: 638085278