Water Inlet Hook-Up; Electrical Supply; Auger Engagement - Cornelius WM600 Installation & Owner's Manual

Ice maker
Hide thumbs Also See for WM600:
Table of Contents

Advertisement

3. Apply a continuous bead of NSF listed silastic sealant (Dow 732 or equal) approximately 1/4–inch inside of
the Unit outline dimensions. Then, position the Unit on the counter within the outline dimensions. All excess
sealant must be wiped away immediately.
IMPORTANT: The WM600 with a full ice storage hopper weighs 450 pounds. Make sure that the
mounting surface is adequately reinforced to support this weight.
The mounting hole dimensions for the brackets are shown in Figure 1A. Use these dimensions to locate the Unit
at the desired height on the wall.
IMPORTANT: Provide support for the Unit until all eight (8)–mounting bolts are installed. Do not hang
the Unit from the top mounting angle bracket only while installing the lower angle.
WATER INLET HOOK–UP:
1. Water Inlet – The fitting is a 1/4"–in. compression fitting located at the bottom of the Unit. Connect water
supply with a 1/4–inch or larger copper or flexible tubing.
2. Water Pressure – Unless otherwise specified, the Unit is designed to operate on a water pressures be-
tween 10 P.S.I. and 90 P.S.I. (NOTE: for pressures above 90 P.S.I; a water pressure regulator must
be installed).
3. Water Cooled Condensers – The inlet uses a 3/8–inch compression fitting. Use a separate 3/8–inch or
larger water line.
4. Filter Conditioners are recommended on supply lines to the Ice Makers. Never run the water supply to
the water cooled condenser through a Filter/Conditioner. It uses up the cartridge unnecessarily and a satu-
rated cartridge can starve the Ice Maker causing premature component damage. Separate water supplies
are recommended.
WM600 – Connect a 1–1/4 inch IPS (or equal) drain line to the1–1/4 inch diameter P–trap at the lower
bottom of the Unit. The line must pitch downward to an open drain and must contain no traps or improper
drainage will result.
CM600 – Connect two (2) 3/4–inch IPS (or equal) drain lines to the 3/4–inch threaded drain connections at
the lower rear of the Unit. These lines must pitch downward to an open drain and must contain no traps or
improper drainage will result. For water–cooled Units, a third 3/4–inch FPT drain fitting is provided for the
condenser drain (see Figure 1B).
NOTE: The Unit must be installed per local plumbing codes.

ELECTRICAL SUPPLY

1. Power Access – Is provided by way of a 7/8–inch diameter hole located on the lower left side of the Unit.
Route incoming power in conduit, to the Ice Maker electrical control box. Make connections to wires pro-
vided in the control box and the ground lug/screw.
2. Fused Line – Should be a dedicated circuit checked and sized according to the electrical rating shown on
the Unit nameplate.
NOTE: The Unit must be installed per local electrical codes.

AUGER ENGAGEMENT

Be certain that the auger is fully engaged to the lower drive and that the extruding head is fully engaged to the
evaporator.