Drain Connection; Electrical Supply; Schematics - Cornelius 500 Series Installation Manual

500, 700, 1000, 2000 - series continuous flow ice maker
Hide thumbs Also See for 500 Series:
Table of Contents

Advertisement

Continuous Flow Icemaker Installation Manual
D
C
RAIN
ONNECTION
1. Overflow Line - is a 3/8" I.D. flexible tube located at the rear of the unit. Extend this line to proper drain.
2. Condenser Outlet - is a 3/8" FPT located on the rear panel.
E
S
LECTRICAL
UPPLY
1. Power Access - is provided with a 7/8" diameter. knockout hole in the rear panel. Route incoming power in
conduit, through rear panel to ice maker electrical control box. Make connections to wires provided in the con-
trol box and ground lug/screw.
For WCC700A, WCC702A and WCC1001A units, 8 ft. 2 inch long (2.4 m) power cord with 3-prong plug
attached to the unit.
!
CAUTION:
Only trained and certified electrical technicians should replace the power cord or the unit should be returned to an
Authorized Service Center for power cord replacement. The replacement cord must meet all requirements of the
original equipment manufacturer.
Failure to comply could result in serious injury, death or damage to the equipment
2. Fused Line - should be checked and sized according to electrical rating shown on unit nameplate.

Schematics

Figure 4. Schematic and Wiring Diagram WCC2001-A and WCF2201-A
Publication Number: 630460174INS
- 8 -
© 2004-2014, Cornelius Inc.

Advertisement

Table of Contents
loading

Table of Contents