A brief explanation of all HID diagnostics is given below.
Diagnostic
System starts
System uptime (s)
Lamp uptime (s)
Ignition driver attempts
Ignition lamp attempts
Failures
Total energy consumed
Energy consumed
(resettable) (Wh)
24H reset expirations
Thermal Guard Protection
EOL driver incandescence
failures
EOL lamp incandescence
© Philips Lighting B.V. 2014
Table 1 HID diagnostics
Description
Number of times the HID driver was switched on (via
the mains).
Total time the HID driver was on.
Total lamp burning time.
Number of times the HID driver attempted to ignite a
lamp.
Number of times the HID driver attempted to ignite
the lamp, since last lamp replacement
Total number of failures detected by the HID driver.
Total energy consumed by the HID driver.
Energy consumed since last user-reset.
HID driver was operating for more than 24 hours; any
failures blocking driver to operate the lamp are cleared
Thermal Guard activated as a consequence of high
temperature level.
End-Of-Life situation showing incandescent mode of
operation of the lamp.
End-Of-Life situation showing incandescent mode of
Philips MultiOne