User Manual
12.3.17
End Of Life indication
Product group
LED
Description
Use this feature to warn the user at the end of the guaranteed lifespan of the LED
module. Once the end of guaranteed life is reached, the device will flash the lamp for
5 seconds and then continue normal operation. LED flashing will happen every time
at startup once the device's working hours have exceeded the number of hours
specified as End Of Life. This feature uses the same burning hours counter as the
Light Source Operating Hours and Constant Light Output features.
Usage
Select the Enable check box to use this feature. Use the slider or the text field to
select a value. The value represents the guaranteed lifetime in hours.
12.3.18
Energy Meter
Product group
FLUO, HID
Description
Use this feature to get an indication of the (total) energy consumption of the device.
Usage
The value for Energy consumed can be reset by selecting the Reset meter check box
followed by clicking Write on the toolbar. The value for Total energy consumed
cannot be reset.
© Philips Lighting B.V. 2014