Access Panel Video Cable; 24V Power Cable; Alarm Input Points; Relay Outputs - NextgenID BioAxs 9750 Installation & Operation Manual

Multi-modal biometric access panel fingerprint recognition with pin and card reader
Table of Contents

Advertisement

BioAxs 9750™ Installation & Operations Manual. Version 1.9
Maximum DCM Extender Cable Distance: 100M (328ft)
DCM Communications Extender Pin Assignments
PIN Wire Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown

Access Panel Video Cable

Suggested P/N:
RG-59U, 23 AWG, solid, braid shield, PVC jacket
RG-6U, 18 AWG, solid, foil/braid shield, PVC jacket
Or Equivalent
Note 1 RCA Video Connector End suitable for the chosen cable type is necessary for
connection to the Composite Video Input of the Door Commander Unit

24V Power Cable

• 14 AWG 2 Conductor Cable

Alarm Input points

• 18 – 22 AWG shielded twisted pair.

Relay outputs

• 18 – 22 AWG shielded twisted pair.

Wiegand Signaling

• 18 AWG 6-conductors shielded twisted pair.

Earth Ground

Access Panel Earth Ground Connection
• 14 AWG Solid - 10 AWG Stranded
Note cabling requirements subject to change without notice. Always consult local building
codes and regulations
Copyright 2005 NextgenID, Inc. All Rights Reserved
21