BioAxs 9800IR™ Installation & Operations Manual. Version 1.9
Maximum DCM Extender Cable Distance: 100M (328ft)
DCM Communications Extender Pin Assignments
PIN
Wire Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
Access Panel Video Cable
Suggested P/N:
•
RG-59U, 23 AWG, solid, braid shield, PVC jacket
•
RG-6U, 18 AWG, solid, foil/braid shield, PVC jacket
•
Or Equivalent
Note 1 RCA Video Connector End suitable for the chosen cable type is necessary for
connection to the Composite Video Input of the Door Commander Unit
Iris Recognition Video Cable
Suggested P/N:
•
RG-59U, 23 AWG, solid, braid shield, PVC jacket
•
RG-6U, 18 AWG, solid, foil/braid shield, PVC jacket
•
Or Equivalent
Note 2 BNC Female Video Connector Ends suitable for the chosen cable type is necessary
for connection to the BNC Iris Video Inputs of the Door Commander Unit and BioAxs 9800IR
Iris Recognition Serial Communications RS422 Cable
UTP Category 5 Ethernet Cable (Plenum / PVC / Riser per Application)
Suggested P/N:
•
Belden 1585A Plenum UTP Cat 5e
•
Belden 1583A PVC UTP Cat 5e
•
Belden 1583R Riser UTP Cat 5e
•
Or Equivalent
Door Commander Unit Connector for IrisAccess™ 3000 Serial communications (DB9M)
The DB9 Male pin configuration of the Iris Recognition Unit serial communication cable for
connection to Door Commander Unit is shown in the following table
Copyright ©2004 NextgenID, Ltd. All Rights Reserved
21