Chapter 3: Hardware Specifications; Power Requirements; Battery Backup; Output Power - NextgenID BioAxs 9750 Installation & Operation Manual

Multi-modal biometric access panel fingerprint recognition with pin and card reader
Table of Contents

Advertisement

BioAxs 9750™ Installation & Operations Manual. Version 1.9

Chapter 3: Hardware Specifications

Power Requirements

Access Panel Power Supply
The BioAxs 9750™ access control panel requires a 24VDC linear (4 amp continuous)
power supply.
NextgenID suggested manufactures and P/Ns:
Electronic Security Devices
Altronix LPS5C24X Linear Power Supply/Charger
Or Equivalents
Door Commander Module (DCM)
120V AC Power
DCM Communications Extender
Input 120V AC
Output DC capacity 15V DC @ 1A

Battery Backup

Access Panel Power Supply
At least 24 VDC (4amp / hr.) battery backup should be supplied or integrated with the
Access Panel 24VDC Power Supply providing 2-4 hours of full operational backup.
Actual backup time is dependent on the load and age of the battery.
Note:
To maintain the maximum backup time, it is recommended that you replace the DC
power supply battery every two to four years. Test regularly according to
manufacturers instructions.
DCM Uninterruptible Power Supply (UPS)
An uninterruptible power supply device providing backup power to the DCM,
Communications Extender and Optional Access Panel Concentrator Hub should be rated
for at least 750VA / 800W, (Input 120V Output 120V) providing at least 2-4 hours of full
operational backup.
Note: To maintain the maximum backup time, test regularly and replace the UPS
batteries every few months.
Note: To maximize continuous operation, It is suggested that all 120 VAC
connections be tied in to the Building Emergency Power when available.

Output Power

505X/506X Door Controller Board (DCB)
12 VDC (10 to 14 volts) 500 mA for readers and accessories requiring 12 VDC
5 VDC, 500 mA output is available for readers and accessories requiring 5 VDC

Earth Ground

Access Panel Earth Ground Connection
Proper Earth Ground Requires <4 ohms resistance when measured against a
known local earth ground.
Copyright 2005 NextgenID, Inc. All Rights Reserved
SPS-20EL
LPS5C24X
18