Chapter 6: Installation

Door Commander Module Installation

The Door Commander Module (DCM) is an industrial small form factor computer that is included
with each BioAxs 9750™ system. The DCM and BioAxs 9750™ must be located within 100
meters of one another. Operating temperature range for the DCM is 32
Located with the DCM is the DCM Communications Extender, this device is responsible for
relaying communications between the BioAxs 9750™ Access Panel and the DCM. The
Communications Extender plugs directly into an available USB port on the DCM.
The DCM and the DCM Communications Extender should be powered thru an Uninterruptible
Power Supply (UPS) (Battery Backup device rated at least 750 VA.
The following sections layout the typical installation procedures for the DCM unit and associated
devices.

Mount the Door Commander Module (DCM) Unit

Upon choosing the location for the DCM
Mount the DCM in the appropriate configuration (Rack or Wall mount) using the supplied
mounting brackets.
Power On
Indicator LED
Figure 7 DCM Front View