BioAxs 9750™ Installation & Operations Manual. Version 1.9
Figure 10: FingerMatch™ Hardware Licensing Device (USB)

Install the Uninterruptible Power Supply (UPS)

Locate the UPS at a distance sufficient to attach the supplied DCM power cable and the supplied
DCM Communications Extender AC Adapter. Connect the UPS to an available 120V AC outlet.
Leave the UPS Un-Powered at this time.
: To ensure optimum performance, most UPS battery systems require at least a
Note
24-hour connection to wall current before use. Always Read and observe manufacturer
instructions before use. Be sure to attach the DCM and DCM Communications
Extender power cables to UPS outlets with Battery backup protection.
DCM & DCM Communications Extender Power Connections
Attach the Supplied DCM power cable to the AC Power Jack located on the rear panel of the
DCM
(figure
8). Plug the cable into a UPS outlet supplying battery backup.
Attach the DCM Communications Extender AC Adapter to the Rear of the Extender Unit. Plug
the Adapter into a UPS outlet supplying battery backup

Install the 24VDC Access Panel Power Supply

Locate the 24VDC power supply according to the guidelines in Chapter 1:Power Requirements.
Always follow the Manufacturers instructions when mounting and installing this unit. When
installing the BioAxs 9750™ Access Control system in integration mode, observe common
grounding requirements. Refer to the Section Wire Installation later in this chapter for attaching
the 2-conductor power cable to the BioAxs 9750™ Access Panel.
BioAxs 9750™ Panel Enclosure Installation
The following sections layout the typical installation procedures for the BioAxs 9750™ unit
Mounting the BioAxs 9750™ Access Panel Enclosure
Select a location for the 9750™ Access Panel (see
Panel). Remove the BioAxs 9750™ access panel from its packing. Detach the BioAxs 9750™
Access Panel Face Plate from the Access Panel Enclosure (Back Box) by using the attached
keys. Set the faceplate aside at this time.