Chapter 1: Preparing for Installation

Site Survey and Preparation

Locating the BioAxs 9750™ Access Panel
The BioAxs 9750™ Access Panel should be mounted on a wall or structure to comply with all
local and federal laws as they apply to the installation site.
Use the following guidelines when choosing a mounting location for the BioAxs 9750™:
The panel is to be located at least 6 inches from the doorjamb and at least 1' from any
adjacent wall.
In order to ensure the highest level of performance for facial recognition, the BioAxs
9750™ should be mounted such that the bottom of the access panel enclosure is at a
height of 50-1/2" inches from the ground.
Consideration should be given to the overall distance from the BioAxs 9750™ to the
Entry point. Select a location that will allow a user to enter the secured facility within
approximately 2 seconds of being granted access by the access control system.
Always mount the BioAxs 9750™ opposite of the opening door swing direction to prevent
interference with individuals exiting the secured area.
1'-0"
B
Typical Mounting Areas
BioAxs 9800IR
Figure 2 Typical Mounting Locations for the BioAxs 9750
Copyright 2005 NextgenID, Inc. All Rights Reserved
Secure Area
6"
A
Non-Secure
FP
IR
Area