Models SRRM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
Item
Cooling capacity
Heating capacity
Sound level
Cooling
Power level
Noise level
Sound level
Heating
Power level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at high)
Air filter, Q'ty
Operation switch
Room temperature control
Pilot lamp
Safety equipment
Liquid line
O.D
Gas line
Refrigerant
Connecting method
piping
Attached length of piping
Insulation
Drain hose
Accessories (including)
Optional parts
Outdoor unit to be combined
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) Capacity indicated is the rated capacity with one unit operating under ISO-T1 standards conditions.
Models
SRRM25ZE-S
W
2500
W
3400
38
53
dB
39
54
mm
kg
W
Cooling
8.5
CMM
Heating
10.0
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
mm (in)
Indoor air temperature
DB
27ºC
20ºC
SRRM35ZE-S
3500
4500
40
55
41
56
230 × 740 × 455
22.0
Centrifugal fan × 2
51
9.0
11.0
Polypropylene net × 1
Wireless-Remote control
M.C thermostat
Frost protection, Serial error protection
Fan motor error protection, Drain error protection
φ 6.35 (1/4")
φ 9.52 (3/8")
Flare connecting
Necessary (Both Liquid & Gas lines)
Connectable
Mounting kit
Wired remote control
SCM60ZD-S
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
SRRM50ZE-S
SRRM60ZE-S
5000
6000
5800
6800
46
49
60
63
46
49
60
63
23.0
10.5
12.5
13.0
15.0
φ 12.7 (1/2")
Standards
WB
24ºC
ISO-T1, JIS C9612
6ºC
ISO-T1, JIS C9612
7