k)
Attach two chains to the intake grille with two screws. [ Figure 7]
l)
Replace the corner panels. Please also close a chain with a screw together then.
m)
Close the intake grille.
(3) Ducted type (SRRM)
(a) Caution for installation
Install the unit with the customer's consent at location that meets the following conditions.
1) Where there are no barriers to the breeze, and where cool/hot air may diffuse throughout the room.
2) A firm location that may sustain the weight of the unit, and do not cause the unit or the ceiling to vibrate.
3) A location that allows room for maintenance.
4) Where wiring and plumbing may be performed with ease.
5) Where water may be drained easily.
6) Where the unit is not influenced by the television, stereo, radio, or the lights.
7) Where the unit is not influenced by high frequency equipment and wiring equipment.
8) Where oil splashes do not occur frequently.
9) Where sunlight and strong lights do not directly hit the receiver.
10) A flat ceiling surface (bottom of ceiling).
(b) Installation of indoor unit
1) Installation dimensions
740
35
670
Hanging bolt pitch
Plan
2) Drilling of holes in the wall and fixture of sleeve
The instructions for installation is the same as the SKM type. Please refer to page 46.
Chain
Front
35
740
[Figure 7]
Side
106
455
Drain hose
(Connection opening diameter ø16)
Chain
38
Gas side pipes
236
Liquid side pipes
135 78