Sediment Trap - L.B. White Pilot Light Ignition Installation And Service Manual

Pilot light ignition agricultural animal confinement building heaters
Hide thumbs Also See for Pilot Light Ignition:
Table of Contents

Advertisement

Installation
Instructions

Sediment Trap

Assemble the tee, nipples and cap together and tighten
securely.
The sediment trap assembly must always be
mounted in a vertical position.
compound that is resistant to both L.P. gas and natural gas
is used in making all connections. Check a a ll c c onnections f f or
gas l l eaks u u sing a a pproved g g as l l eak d d etectors.
2.7-1 1
Make sure pipe thread
Gas C C ontrol
Valve I I nlet
Make certain that a sediment trap is installed at the gas
valve inlet to prevent foreign materials (pipe compound, pipe
chips and scale) from entering the gas valve. Debris blown
into the gas valve may cause a malfunction resulting in a
serious gas leak that could result in a possible fire or
explosion causing loss of products, building or even life. A
properly installed sediment trap will keep foreign materials
from entering the gas valve and protect the safe functioning
of that important safety component.
Tee
5 i i n.
Nipple
3 i i n.
Nipple
Cap
August 1999