BP-PR PLUS series
Test functions
Example:
In the following two figures, the printout in Monitor mode is contrasted with the "normal" printout of a
label.
Fig. 17: Example label
Fig. 18: Printout of the example label in ASCII Dump Mode
5.7

Test grid

The Test grid function prints out the geometric pattern on a background grid. This allows you to
assess the evenness of the print quality.
The printout occurs using the heat level and print speed specified in the Setup > Print param. menu.
The printout occurs without taking the label gaps into consideration. This is why endless media are most
suitable for this purpose.
1. Insert printable medium (labels, endless paper) which extends across the entire printing width.
2. If the printout is to occur using thermal transfer printing, insert transfer ribbon with the maximum
width.
3. Press the menu button.
4. Select Test > Test grid menu.
5. Start printout with the ↵ button.
The geometric pattern is printed every 5 seconds once the Test grid function is started. You can
adjust the printer during the pauses between the printouts.
You can end the printout of the test grid with the cancel button.