BP-PR PLUS series
Test functions
5.5

Device list

The Device list function prints out the most important information on hardware components of the
printer and connected devices. The printout occurs using the heat level and print speed specified in the
Setup > Print param. menu.
The printout occurs without taking the label gaps into consideration. This is why endless media are most
suitable for this purpose.
1. Insert printable medium (labels, endless paper) which extends across the entire printing width.
2. If the printout is to occur using thermal transfer printing, insert transfer ribbon with the maximum
width.
3. Press the menu button.
4. Select Test > Device list menu.
5. Start printout with the ↵ button.
You can cancel the printout with the cancel button.
Fig. 15: Device list
Name
CPU
TPH
I/F [x]
USB [a]
[b/c]
Speed
Tab. 19: Parameters of the Device list
42
Information
Type and serial number of the CPU PCB
Revision of CPU PCB and FPGA
Resolution and heating point number of the installed thermal printhead.
Type of interfaces installed
x: Number of interface
Type and revision of installed USB devices
a: number of USB device
b: number of USB device to which device a is connected
c: number of interface of device b to which device a is connected
Speed: data transfer speed (low, full, high)
The following properties are only displayed when the service key is inserted:
Mfr.: Manufacturer ID. This identifies the manufacturer of the USB device
Class: Code for the USB device class
Protocol: Code for the type of communication with the USB device
Phase: Internal value for troubleshooting