Mitsubishi Electric Mr.SLIM PUHZ-RP1.6VHA Technical & Service Manual page 79

Split-type, heat pump air conditioners
Hide thumbs Also See for Mr.SLIM PUHZ-RP1.6VHA:
Table of Contents

Advertisement

8 8 Registering the settings from steps 3 3 to 7 7 into memory
The mode and setting numbers (1)(2) will start to flash when the MODE button E is pressed and registration will begin. The
numbers are set when the flashing stays lit.
WIf [---] appears in the room temperature display as the mode/setting number, or if a flashing [88] display appears, a transmis-
sion problem may have occurred. Check to see if there are some sources of transmission interference (noise) nearby.
9 9 Registering other settings simultaneously
Repeat steps 3 to 8 to make other function settings.
0 0 Completing the function settings
Press A FILTER and B TEST RUN buttons simultaneously for at least two seconds. (For modes 15 and higher, press J and
B simultaneously for at least 2 seconds.) After a while, the function selection screen will disappear and air conditioner OFF
display will appear.
FUNCTION
1
2
WDo not use the remote controller for 30 seconds after completing the function
setting. (Any requests will be rejected.)
FUNCTION
Note
Make sure to check all settings with
you have changed the settings of indoor units by this procedure after installa-
tion construction.
1
2
79
FUNCTION
and etc. on the checklist of table 1 if

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents