10-1. Installation Diagram of Indoor and Outdoor Units
3
Batteries
2
Wireless remote control
Remark :
• Detail of accessory and installation parts can see in the accessory sheet.
• Some pictures might be different from the actual parts.
å
CAUTION
Install in rooms that are 13 m
3
or larger.
If a leak of refrigerator gas occurs inside the room, an oxygen defi ciency
can occur.
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
2 Wireless remote controller

10. INSTALLATION PROCEDURE

5
6
Filter
,
8
Pan head
4
wood screw
1
Installation
Hook
plate
Shield pipe
Remote control holder
3 Batteries
– 40 –
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Left
Bottom
Rear
right
left
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam