Daewoo DWC-121R Service Manual
Hide thumbs Also See for DWC-121R:

Advertisement

Manual de Servicio
Acondicionador de Aire Tipo Ventana
Modelo :
DWC-121R
DWA-121R
DWA-122R
DWB-121R
DWB-122R
DWB-123R
DWA-150R
DWA-151R

Advertisement

Table of Contents
loading

Summary of Contents for Daewoo DWC-121R

  • Page 1 Manual de Servicio Acondicionador de Aire Tipo Ventana Modelo : DWC-121R DWA-121R DWA-122R DWB-121R DWB-122R DWB-123R DWA-150R DWA-151R...
  • Page 2: Table Of Contents

    Contents CONTENTS 1. Specifications ....................2 2. Operation .....................3 3. Wiring Diagram..................10 4. Refrigerant Cycle ..................11 5. Control Block Diagram.................12 6. Circuit Diagram..................13 7. Trouble Shooting..................16 8. Key Components of Electronic Circuit ............26 9. Disassembly Instructions ................28 10. Exploded Diagram and Parts List..............30...
  • Page 3: Specifications

    1. SPECIFICATIONS MODEL DWC-121R DWA-121R DWA-122R DWB-121R DWB-122R DWB-123R DWA-150R DWA-151R ITEM Function Cooling only Power source AC 115V, 60Hz AC 208~230V, 60Hz AC 220~240V, 50Hz AC 220~230V, 50Hz AC 240V, 50Hz AC 208~230V, 60Hz Btu/h 12,100 12,000 12,000 11,700...
  • Page 4: Operation

    2. OPERATION PARTS OF NAME AND FUNCTION -121R/DW -122R/DWB-123R/DWA-150R/DWA-151R (NOTE: A or B or C) PART NAME PART NAME AIR FILTER BLADE HORIZENTAL GRILLE FRONT AIR VENT CABINET FRAME GUIDE TOP BLADE VERTICAL FRAME WINDOW KIT PANEL CONTROL SHUTTER WINDOW REMOTE CONTROLLER...
  • Page 5: Remote Controller

    REMOTE CONTROLLER REMOCON SIGNAL TRANSMITTER TIMER/CANCEL • Everytime you push this button, timer is set as follow. (1Hr 2Hr 3Hr 4Hr 5Hr 6Hr 8 Hr 10Hr 12Hr 16Hr 20Hr 24Hr CANCEL). SLEEP After the unit is timed, if this button is TIMER/ •...
  • Page 6: Remote Controller Display

    REMOTE CONTROLLER DISPLAY MODE DISPLAY • It displays the operating mode. TEMP./TIMER DISPLAY • It displays the temperature and the timer. REMOCON SIGNAL RECEIVER TEMPERATURE SET BUTTON • It is the button to set the desired room temperature. The temperature can be set within a range from 16°C (60°F) to 32°C (90°F) by 1°C (1°F) SENSOR...
  • Page 7 Replacing Batteries Remove the COVER from Insert two battaries. Re-attach the cover. the back of the remote • Be sure that the (+) and • Slide it back into position controller. (–) directions are correct • Slide the cover • Be sure that both batteries according to the arrow are new direction...
  • Page 8 DESCRIPTION OF FUNCTIONS OFF-Timer If you set time in OFF-Timer Mode, the unit will stop at the set time. Unit ON Unit OFF SET Time HOUR ON-Timer If you set time in ON-Timer Mode, the unit will run at the set time. Unit ON Unit OFF SET Time...
  • Page 9: Fan Speed

    Fan Speed (1) Motor speed (high speed, normal speed, low speed). (2) Remote controller setting fan speed. (H, M, L) (3) Relation of operating mode between fan speed. FAN ONLY COOL TURBO Sleep Mode (1) When you are going to sleep, select sleep button in remocon and the unit controls the room to the desired temperature.
  • Page 10 Auto Swing (1) When you push this button, in remocon the left/right flap move to the position of keeping the room temperature comiortable. (2) The air discharge direction procedure is below. Auto swing Fixed Turbo Mode(Powerful Cooling) (1) Cooling Condition Fan Speed: High speed Set temperature:16˚C(Fixed) Compressor and Fan...
  • Page 11: Wiring Diagram

    3. WIRING DIAGRAM...
  • Page 12: Refrigerant Cycle

    Blower fan Capillary tube Accumulator MOTOR Compressor Propeller fan Condenser Model Name DWA-121R DWA-122R DWB-121R DWB-122R DWB-123R DWC-121R DWA-150R DWA-151R Contents ID1.6Ø x L800 ID1.6Ø x L900 ID1.6Ø x L800 ID1.6Ø x L600 Capillary tube 740g 790g 730g 690g 760g...
  • Page 13: Control Block Diagram

    5. CONTROL BLOCK DIAGRAM Front PCB Remote controller 88 LED Remocon Signal Operating Mode Fan mode Lamp Receiver Fan speed Turbo mode Lamp Timer selection Cooling mode Lamp Auto swing Room Temp Lamp Temp setting Desired Temp Lamp ON/OFF Timer Lamp Sleep Main PCB DC 5V...
  • Page 14: Circuit Diagram

    6. CIRCUIT DIAGRAM...
  • Page 15: Part List

    Part List MAIN PCB ASS’Y(3104302300) PART NAME SPEC PART CODE Q’TY REMARK IC MICOM TMP47P443N 13GSHK64-- IC DRIVE TD62004AP 13GT62004A IC DRIVE TD62783AP 13GT62783A IC REGULATOR KIA7812P 1KA7812AP- IC REGULATOR KIA7805P 1KA7805AP- IC RESET KIA7042P 1KA7042P-- FUSE CLIP AFC-520 3107000600 FUSE FUSE 125V, 5A...
  • Page 16 Front PCB ASS’Y(3104302400) PART NAME SPEC PART CODE Q’TY REMARK LED DISPLAY 3103003700 DISP C-CERA 103Z 50VDC CXCH1H103M RECEIVE MODULE PIC-26043TH2 1PC26043TH REMO DLSO-5031D DDLS05031D DLG-5031D DDLG5031D- SWITCH TACT JTP1212 3109300900 DIODE 1N4148 DZN4148A-- D1-6 WAFER SMAW250-08 3108804800 WAFER SMAW250-10 3108802400 FR-1 3104302200...
  • Page 17: Trouble Shooting

    7. TROUBLE SHOOTING Self-Diagnostic Function 1) Error Code 1(Er) Check the connector of room air thermistor. (or connecting wire) Check soldering of connecting on control P.C.B. (Error of soldering or short) Check the resistance of room air thermistor. “Press the temperature Keys (Up & Down), Error code is displayed.” Unit Not Run The power is applied to the unit Rating voltage...
  • Page 18 Only Compressor Do not Run - Check the following at cooling mode Check the Main P.C.B Check the voltage between “POWER ” Rating voltage the circuit for relay less than 90% driving. “RL1 ” of Main P.C.B Rating voltage more than 90% Check the connecting Rating voltage wire between Main...
  • Page 19 PCB DRIVING DESCRIPTION...
  • Page 20 Power Supply(1) AC 220V VAR1 POWER 2200/35V TRANS 7805 7812 100/16V 470/25V DESCRIPTION DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Fan Motor Driving Relay, Buzzer Driving, Swing Motor Driving Relay and LED Display. AC voltage of secondary Power Transformer is rectified by 4 Diode, and it is filtering by Main Condensor C2.
  • Page 21 Oscillation(2) MICOM 8 MHz DESCRIPTION Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency. Ocillatory wave is as following Fig 2-1. -10% +10% Fig 2-1...
  • Page 22 Sensor(3) Room temperature Sensor Input ROOM:PT-K43C MICOM 12.7K 0.01 DESCRIPTION Number 15 of Micom is Terminal of A/D convertor Input. Room temperature is sensing by change of Thermister Resistance, Micom is put in 5V by ratio between R3 (12.7KΩ) and Room sensor. Relation between temperature and voltage is following Table 3-1.
  • Page 23 Remote Controller(4) DESCRIPTION Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 5, which is gotten field of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1. But in Secondary Wave Custom Code is Reversed Face. 4.5ms 16bit 16bit...
  • Page 24 Micom Power Supply(5) 100µF/16V MICOM DESCRIPTION MICOM Power is supplied 5V at Number 28 using VDD, Number 6 using Analog Reference of A/D Converter. C9, C10 is Ripple filter.
  • Page 25 Reset(6) 5.6K MICOM 7042 + C11 RESET IC 1µF/50 DESCRIPTION Voltage less than about 4.2V put in Micom Terminal of Number 6 and then Micom reset. Reset IC detect Power ON and Voltage greater than 4.2V, and then send Reset Signal. Vcc (+5V) 4.2V DELAY TIME...
  • Page 26 Function Selecting(7) MICOM TEST ˚F/ ˚C DESCRIPTION Selecting Function is as following table 9-1. Selection S/W SHORT OPEN Function ˚F / ˚C ˚F ˚C TEST Table 9-1...
  • Page 27: Key Components Of Electronic Circuit

    8. KEY COMPONENTS OF ELECTRONIC CIRCUIT (1) IC3 (MICOM) TMP47C443N XOUT TEST HOLD (KE0) Display Out R92 (SCK) RESET Fan Speed(Hi) Display Out R91 (SO) Remocon Signal Display Out R90 (SI) R71 (PULSE) Display Out R83 (T1) R72/VAREF Display In, Key Out Comp R82 (INT1/ZIN) R40 (AIN0)
  • Page 28 (3) U2(TD62004AP) DARLINGTON ARRAYS IN1 1 16 OUT 1 KID65004AP IN2 2 15 OUT 2 IN3 3 14 OUT 3 10.5K IN4 4 13 OUT 4 IN5 5 12 OUT 5 7.2K IN6 6 11 OUT 6 IN7 7 10 OUT 7 GND 8 9 COMMON FREE WHEELING DIODES...
  • Page 29: Disassembly Instructions

    9. DISASSEMBLY INSTRUCTIONS Please refer to the chapter 10 (Exploded diagram and parts list). Before service of 1. Stop the unit, remove the power cord from the receptacles. any part. 2. Move the unit to the safe location for the suitable work. Ass’y Fan Motor 1.
  • Page 30: How To Remove The Front Grille

    • HOW TO REMOVE THE FRONT GRILLE 1. Remove the Air Filter from the front grill by pulling to right. 2. Remove two screw tapping from front grille. 3. Push the “LATCH position” at the right side of cabinet. Push Screw Fig.
  • Page 31: Exploded Diagram And Parts List

    10. EXPLODED DIAGRAM AND PARTS LIST DWA-121R, DWA-122R, DWB-121R, DWB-122R, DWB-123R, DWC-121R, DWA-150R, DWA-151R PARTS LIST  Caution: In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr)
  • Page 32 COVER MOTOR 3104202000 PANEL HOUSING SGCC T1.0 3102000500 FIXTURE RUBBER 24-1 3100000010 BUSHING GUIDE 3108004920 MOTOR FAN DAEWOO MOTOR (AM 12DWD10) DWC-121R(ONLY) 3108005020 MOTOR FAN DAEWOO MOTOR (AM 12DWD12) DWA-121R, 122R(ONLY) 3108006000 MOTOR FAN OBM2502U1 DWA-121R, 122R(ONLY) 3108005110 MOTOR FAN...
  • Page 33 3109507010 CAPACITOR 5/30µF,400VAC DWB-122R(ONLY) 3109503410 CAPACITOR 4/25µF,370VAC DWA-150R,151R(ONLY) 3101201600 CLAMP CAPACITOR SGCC T0.8 3108004800 MOTOR SWING 120VAC 60HZ DWC-121R(ONLY) 3966031000 MOTOR SWING 200/220V 50/60HZ DWA-121R,122R,150R,151R,DWB-121R,122R,123R(ONLY) 3100508510 BOX CONTROL SGCC T0.8 3106600500 SCROLL UPPER 3103002800 HOLDER SCROLL SGCC 3104409300 PIPE RUBBER BUTYL...
  • Page 34 DWA-121R, DWA-122R, DWB-121R, DWB-122R, DWB-123R, DWC-121R, DWA-150R...
  • Page 35 A-151R EXPLODED DIAGRAM...
  • Page 36 DAEWOO ELECTRONICS CO., LTD. 686, AHYEON-DONG MAPO-GU SEOUL, KOREA C.P.O. BOX 8003 SEOUL, KOREA TELEX: DWELEC K28177-8 CABLE: “DAEWOOELEC” FAX: 02) 590-6291 TEL: 02) 360-7114/590-6151~5 http://www.dwe. daewoo.co.kr S/M NO.: DWC121R030 PRINTED DATE: DEC. 2000...

Table of Contents