Daewoo DWC-055RL Use & Care Manual
Daewoo DWC-055RL Use & Care Manual

Daewoo DWC-055RL Use & Care Manual

Window type room air conditioner

Advertisement

ROOM AIR CONDITIONER

USE & CARE MANUAL
WINDOW TYPE ROOM AIR CONDITIONER
DWC-055RL
MODEL #:
DWC-063RL
C
R
UL and
US
CUL listed
LISTED
Please read carefully and thoroughly this manual before
operating the unit.
If you still have any difficulties or problems, consult your
dealer for help or
ELECTRONICS.
Please keep this manual well.
W1
S/N : 3113905610

Advertisement

Table of Contents
loading

Summary of Contents for Daewoo DWC-055RL

  • Page 1: Room Air Conditioner

    ROOM AIR CONDITIONER USE & CARE MANUAL WINDOW TYPE ROOM AIR CONDITIONER DWC-055RL MODEL #: DWC-063RL UL and CUL listed LISTED Please read carefully and thoroughly this manual before operating the unit. If you still have any difficulties or problems, consult your dealer for help or ELECTRONICS.
  • Page 2 PRECAUTIONS FOR PROPER USE OF AIR CONDITIONER Please observe the following instructions. 1. Operate the Selector Switch to run or stop the unit. - Do not use Main Power Switch or Auxiliary Power Switch to operate unit. 2. Do not stick anything into the air outlet or inlet. - It is dangerous and it can cause injury or damage.
  • Page 3: Table Of Contents

    7. ELECTRICAL REQUIREMENTS .................17 • ELECTRICAL GROUNDING INSTRUCTIONS. • USAGE OF POWER CORD(AFCI & LCDI) 8. BEFORE CALLING FOR SERVICE..............18 GENERAL SPECIFICATIONS MODEL DWC-055RL / DWC-063RL ITEM POWER SOURCE AC 115V, 60Hz, SINGLE PHASE 17.3(W) x 12.3(H) x 15.2(D) inch DIMENSIONS...
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS • WINDOW REQUIREMENTS These instructions are provided for a standard double hung window or mobile home double hung window installation in windows 21.7in (550mm) to 34.6in (880mm). The upper and lower sash must open sufficiently to allow a clear vertical opening of 12.7in (323mm) from the bottom of the sash to the window stool.
  • Page 5: Safety Instructions

    • SAFETY INSTRUCTIONS The receptacle should be an individual branch circuit used only for this air conditioner. Be sure the electrical service is adequate for the model air conditioner you have chosen. The complete electrical rating of your air conditioner is stated on the name plate located at the unit’s side. Be sure the plug receptacle is close enough for the power cord to reach it.
  • Page 6: Step1-Prepare Components For Installation

    • Step 1 - Prepare Components For Installation 1. Open the components box for installation • SCREW TYPE 2. Check components for installation as follows. Type A Type B Type C Type D • Sill Bracket (1 piece) • Window Shutter (2 pieces) •...
  • Page 7: Step3-Placing Unit In Window

    • Step 3 - Placing Unit in Window CAUTION 1. The unit is heavy. To avoid injury or accident, it is strongly recommended that you have additional help when lifting the unit. 2. Personal injury or property damage may result if unit falls from window. 1.
  • Page 8: Step5-Secure Window Shutter

    • Step 5 - Secure Window Shutter CAUTION Do not drill into window sash until window has been inspected to make sure drilling or screw will not damage any locking or lifting mechanism located in the frame. WINDOW KIT FRAME To provide a proper seal, pull each expandable side Window Shutter out Screw (Type C) WINDOW...
  • Page 9: Names Of Major Components

    NAMES OF MAJOR COMPONENTS PART NAME PART NAME CABINET AIR FILTER BLADE VERTICAL FRAME GUIDE TOP COOL AIR DISCHARGE FRAME WINDOW KIT GRILLE FRONT SHUTTER WINDOW PANEL CONTROL REMOTE CONTROLLER AIR INTAKE...
  • Page 10: Operation Instructions

    OPERATION INSTRUCTIONS • DISPLAY MODE DISPLAY • It displays the operating mode. REMOTE SIGNAL TEMP./TIMER DISPLAY TEMPERATURE SET RECEIVER • It displays the • It is the button to set the desired temperature and the room temperature. timer. The temperature can be set within a range from 16°C (60°F) to 32°C (90°F) by 1°C (1°F) POWER ON/OFF SWITCH...
  • Page 11: Remote Control

    • REMOTE CONTROL REMOTE SIGNAL TRANSMITTER POWER ON/OFF • To turn the unit ON, push this button. To turn the unit OFF, push this button, again. TEMPERATURE • It is the button to set the room in MODE the desired room temp. •...
  • Page 12 FUNCTION OPERATION DISPLAY POWER ON 1. The unit starts working. 1. Current room temperature is (It is delayed 3 minutes after main displayed. power source is supplied.) 2. ‘COOLING’ lamp lights. POWER 2. Default mode is ‘COOLING’ mode. 3. Default desired room temperature is ROOM Push POWER button ‘26°C’...
  • Page 13 FUNCTION OPERATION DISPLAY FAN MODE 1. The Fan works only. 1. Current room temperature is 2. In this mode, the unit circulate room air. displayed. MODE 3. Fan speed can be changed. 2. ‘FAN’ lamp lights. MODE ROOM TEMP . TEMP Push the ‘MODE’...
  • Page 14 FUNCTION OPERATION DISPLAY ON TIMER 1. Timer is changed to as follows by 1. ‘TIMER’ lamp lights. pushing “TIMER/CANCEL” button. 2. Setting time is displayed. TIMER/ CANCEL (1hr 2hr 3hr 4hr 5hr 6hr 8hr ROOM 10hr 12hr 16hr 20hr 24hr cancel) TEMP .
  • Page 15: How To Insert Batteries

    • HOW TO INSERT BATTERIES Remove the COVER from Insert two battaries. Re-attach the cover. the back of the remote • Be sure that the (+) and (–) • Slide it back into position controller. directions are correct • Slide the Cover according •...
  • Page 16: General Information

    GENERAL INFORMATION • CHANGING AIR FLOW DIRECTION Air flow deflectors divert air from center flow to left or right. Adjust deflectors for desired air flow pattern. • AIR FLOW AROUND UNIT Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow.
  • Page 17: Care And Maintenance

    CARE AND MAINTENANCE CAUTION To avoid death or personal injury due to electrical shock, turn fan control OFF and unplug power cord before cleaning or performing maintenance. After cleaning or performing maintenance, reconnect power. • AIR FILTER Clean the air filter, which removes dust inside the room. It should be washed at least once every week during operation.
  • Page 18: Electrical Requirements

    ELECTRICAL REQUIREMENTS • ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code.
  • Page 19: Troubleshooting

    BEFORE CALLING FOR SERVICE When you find something wrong with your room air conditioner, please carefully check the following items. If you are unable to find the cause of trouble, contact your service dealer. Difficulty Possible Cause Suggested Solution • Air conditioner does •...
  • Page 20: Limited Warranty

    Daewoo authorized service center. To establish and receive warranty service at our store, dealer or our authorized service center, a sales receipt or bill of sales is required for proof of purchase.

This manual is also suitable for:

Dwc-063rl

Table of Contents