TABLE OF CONTENTS ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 1. PRECAUTION ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 2. GENERAL SPECIFICATIONS ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 3. NAMES OF MAJOR COMPONENTS ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 4. FUNCTION OF MAIN COMPONENTS ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 5. GENERAL INFORMATIONS ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 6. CARE AND MAINTENANCE ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 7. TROUBLE SHOOTING GUIDE ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ 8. HOW TO DISASSEMBLE ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ...
1. PRECAUTION Please observe the following instructions. 1. Turn off unit. Make sure the unit is OFF and the AC cord is unplugged before repairing or servicing. 2. In case of checking the circuit unavoidably while the unit is connected with power source, be careful not to connect with the part of electric charge.
2. GENERAL SPECIFICATIONS MODEL DWC-070C DWC-091C ITEM Function Cooling only Power source AC 115V, 60Hz, Single phase Btu/h 7,390 Btu/h 9,000 Btu/h Cooling Capacity Kcal/h 1,862 Kcal/h 2,268 Kcal/h Btu/wh 10.0 Btu/wh 9,6 Btu/wh Energy Efficiency Ratio Kcal/wh 2.52 Kcal/wh 2.42 Kcal/wh...
3.NAMES OF MAJOR COMPONENTS ¤ ¤æ ¤ PART NAME PART NAME CABINET AIR INTAKE BLADE VERTICAL AIR FILTER COOL AIR DISCHARGE CONTROL PANEL GRILL FRONT PLATE WINDOW TOP KNOB SELECTOR FRAME WINDOW KIT KNOB THERMOSTAT SHUTTER WINDOW...
4. FUNCTION OF MAIN COMPONENTS 1. ROTARY SWITCH (SELECTOR) Please refer to the part of selector in the chapter 9 (Wiring Diagram). The rotary switch (selector) controls the fan motor’s rotation speed, and has five positions. The function of the five position is as follow. OFF: This position stops all operations of the air conditioner.
5. GENERAL INFORMATIONS 1. CHANGING AIR FLOW DIRECTION Air flow deflectors divert air from center flow to left or right. Adjust deflectors for desired air flow pattern. 2. AIR FLOW AROUND UNIT Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow.
6. CARE AND MAINTENANCE 1. AIR FILTER Clean the air filter, which removes dust inside the room. It should be washed at least once every week during operation. 1. Remove the Air Filter from the front grill by pulling up. 2.
7. TROUBLE SHOOTING GUIDE TROUBLE SITUATION ANALYSIS CAUSE REMEDY Fan motor and 1. Power failure 1) Power plug 1) Power failure Consult your electric company ¡ compressor do not 2) Circuit breaker 2) Circuit breaker is tripped In case of a breaker, turn it on ¡...
Page 9
TROUBLE SITUATION ANALYSIS CAUSE REMEDY The compressor runs 1) Fan Blocked by others Repair ¡ ¡ but the motor doesn’t 2) Fan motor 3) Capacitor Disconnection or burned-out Replace the fan motor ¡ ¡ 4) Fan motor circuit electric cord Failure malfunction of contact Replace ¡...
8. HOW TO DISASSEMBLE Please refer to the chapter 11 (Exploded diagram and parts list). Before service of 1. Stop the unit, remove the power cord from the receptacles. any part. 2. Move the unit to the safe location for the suitable work. Ass’y Fan Motor 1.
DWC-091C This instrument is listed by Underwriter¡ ¡ fl fl s Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety standards against X-radiation, LISTED ROOM AIR CONDITIONER fire, casualty and electrical hazards. 39WK DAEWOO ELECTRONICS CO., LTD.
Need help?
Do you have a question about the DWC-070C and is the answer not in the manual?
Questions and answers