Sharp FO-4450 Service Manual page 44

Hide thumbs Also See for FO-4450:
Table of Contents

Advertisement

FO-4450U/FO-CS1
SW29 No. 5 Reserved
Set to "1".
SW29 No. 6 ~ No. 8 Reserved
Set to "0".
SW30 No. 1 ~ No. 4 Reserved
Set to "0".
SW30 No. 5, No. 6 Reserved
Set to "1".
SW30 No. 7 Reserved
Set to "0".
SW30 No. 8 Reserved
Set to "1".
SW31 No. 1 ~ No. 8 Reserved
Set to "0".
SW32 No. 1 Reserved
Set to "1".
SW32 No. 2 Reserved
Set to "0".
SW32 No. 3 Reserved
Set to "1".
SW32 No. 4 ~ No. 6 Reserved
Set to "0".
SW32 No. 7 Reserved
Set to "1".
SW32 No. 8 Reserved
Set to "0".
SW33 No. 1 ~ No. 3 Reserved
Set to "1".
SW33 No. 4 Reserved
Set to "0".
SW33 No. 5 ~ No. 7 Reserved
Set to "1".
SW33 No. 8 Reserved
Set to "0".
SW34 No. 1, No. 2 Reserved
Set to "1".
SW34 No. 3 ~ No. 8 Reserved
Set to "0".
SW35 No. 1 Reserved
Set to "0".
SW35 No. 2, No. 3 Reserved
Set to "1".
SW35 No. 4 ~ No. 8 Reserved
Set to "0".
SW36 No. 1 Reserved
Set to "1".
SW36 No. 2 ~ No. 8 Reserved
Set to "0".
SW37 No. 1 ~ No. 5 Reserved
Set to "0".
SW37 No. 6 Reserved
Set to "1".
SW37 No. 7 Reserved
Set to "0".
SW37 No. 8 Reserved
Set to "1".
SW37 No. 5 ~ No. 8 CI signal off detect enable time
Used to set the continuous detection time during OFF period of CI sig-
nal. Normally set to 700ms, where the short ring (500ms: OFF period)
cannot be detected. Therefore, selection of 350ms is allowed.
SW38 No. 1 ~ No. 8 Reserved
Set to "0".
SW39 No. 1 ~ No. 7 Reserved
Set to "0".
SW39 No. 8 Reserved
Set to "1".
SW40 No. 1 Reserved
Set to "1".
SW40 No. 2 ~ No. 4 Reserved
Set to "0".
SW40 No. 5, No. 6 Reserved
Set to "1".
SW40 No. 7, No. 8 Reserved
Set to "0".
SW41 No. 1 Reserved
Set to "1".
SW41 No. 2 ~ No. 4 Reserved
Set to "0".
SW41 No. 5 Reserved
Set to "1".
SW41 No. 6 ~ No. 8 Reserved
Set to "0".
SW42 No. 1 ~ No. 8 Reserved
Set to "0".
SW43 No. 1 ~ No. 8 Reserved
Set to "0".
SW44 No. 1 ~ No. 8 Reserved
Set to "0".
SW45 No. 1 ~ No. 8 Reserved
Set to "0".
SW46 No. 1 ~ No. 8 Reserved
Set to "0".
SW47 No. 1 ~ No. 8 Reserved
Set to "0".
SW48 No. 1 ~ No. 8 Reserved
Set to "0".
SW49 No. 1 ~ No. 8 Reserved
Set to "0".
SW50 No. 1 ~ No. 8 Reserved
Set to "0".
SW51 No. 1 ~ No. 8 Reserved
Set to "0".
SW52 No. 1 ~ No. 8 Reserved
Set to "0".
SW53 No. 1 ~ No. 8 Reserved
Set to "0".
SW54 No. 1 ~ No. 8 Reserved
Set to "0".
SW55 No. 1 ~ No. 4 Duplex scan (Black line detection when
reading for transmission)
Set criteria to detect a black line when reading for transmission.
SW55 No. 5 ~ No. 8 Duplex scan (Black page detection when
reading for transmission)
Set criteria to detect a blank page when reading for transmission.
SW56 No. 1 ~ No. 4 Duplex scan (Black line detection when
reading for copies)
Set criteria to detect a black line when reading for copies.
SW56 No. 5 ~ No. 8 Duplex scan (Black page detection when
reading for copies)
Set criteria to detect a blank page when reading for copies.
SW57 No. 1 ~ No. 8 Reserved
Set to "0".
2 – 30
manuals4you.com
manuals4you.com

Advertisement

Table of Contents
loading

Table of Contents