Verifying The Installation - HP 1910 Getting Started Manual

1910 series gigabit ethernet switch
Hide thumbs Also See for 1910:
Table of Contents

Advertisement

Tighten the screws on the plug with a flat-blade screwdriver to secure the plug in the RPS receptacle
3.
(see callout 2 in
Connect the other end of the power cord to the RPS.
4.
Make sure that the RPS is supplying power and verify that the RPS status LED is ON.
5.
Figure 43 Connect the RPS cable to the –52 to –55 RPS receptacle

Verifying the installation

After you complete the installation, verify that:
There is enough space for heat dissipation around the switch, and the rack or workbench is stable.
The grounding cable is securely connected.
The correct power source is used.
The power cords are properly connected.
All the interface cables are cabled indoors. If any cable is routed outdoors, verify that the socket
strip with lightning protection and lightning arresters for network ports have been properly
connected.
Figure
43).