Minimum Height Of Flue System Exit - Quadra-Fire 57ST-ACC-AU Installation Instructions Manual

Step top acc wood burner
Hide thumbs Also See for 57ST-ACC-AU:

Advertisement

R
GENERAL INSTRUCTIONS FOR FLUE SYSTEM
1. Unpack the Flue Mounted Shield, detach the three brackets and familarize yourself with the illustra-
tions.
2. Using a sharp knife or razor blade, carefully cut through the plastic film on the "inside face" where
it meets the outer shield (refer sketch). Cut along the full length of the Flue Mounted Shield on both
side, then peel off and fully remove the plastic film from the stainless steel inner shield.
3. Peel back and fully remove the plastic film from the outer shield.
4. Fit the top bracket to the Flue Mounted Shield as illustrated ensuring the rear mid section of the
bracket fits "outside" while the two outer sections of the bracket fit "inside".
5. Fit the appropriate lower bracket to your woodfire.
Lower Bracket "5B suitable for all other woodfires without an inner rear heatshield. On certain model
woodfires without a raised flue spigot it will be necessary to cut off both the lower outer legs from the
bracket "5B" leaving the entral tongue to locate inside the flue outlet only.
Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will
mount lower onto the appliance.
The Flue Mounted Shield then locates into the two notches provided n bracket "5B" as illustated.
6. Once the Flue Mounted Shield is fitted in position onto either of the two lower mounting brackets,
check to ensure a large gap is not present between the top of the woodfire and the base of the Flue
Mounted Shield, as this may result in a hot spot on the rear wall directly behind the flue outlet. If your
woodfire has a lift off top grill the Flue Mounted Shield should be raised sufficiently to enable the top
grill to be removed.
7. Using the pre-punched holes in the two tabs provided on the top bracket as guides, drill into the
flue pipe and secure the top bracket to the flue pipe with two stainless steel rivets (not supplied).

MINIMUM HEIGHT OF FLUE SYSTEM EXIT

Fig. 8
3000
increase as necessary
until nothing within
3000mm of flue top
Any nearby structure
July 19, 2012
3000
More than 3000
or less
600 min.
7038-201
5700 Step Top ACC Wood Burner
3000
increase from 1000mm
minimum until clear within
3000mm of flue top
Page 9