D. Chimney Height / Rise and Run
This product was designed for and tested on a 6 inch
(152mm) chimney, 14 to 16 feet (420-480cm) high,
(includes appliance height) measured from the base of the
appliance. The further your stack height or diameter varies
from this configuration, the greater the likelihood it may
affect performance.
Chimney height may need to be increased by 2 - 3% per
each 1000 feet above sea level. It is not recommended
to use offsets or elbows at altitudes above 4000 feet
above sea level or when there are other factors that affect
flue draft.
WARNING
Fire Risk. Inspection of Chimney:
Chimney must be in good condition.
Meets minimum standard of NFPA 211
Factory-built chimney must be 6 inch
(152mm) UL103 HT.
WARNING
Asphyxiation Risk.
DO NOT CONNECT THIS APPLIANCE
TO A CHIMNEY FLUE SERVICING
ANOTHER APPLIANCE.
DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.
May allow flue gases to enter the house.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to the owner's information manual provided with
this appliance. For assistance or additional information
consult a qualified installer, service agency or
your dealer.
E. Venting Components
Chimney Connector:
It is also known as flue pipe or appliance pipe. The chimney
connector joins the appliance to the chimney. It must be
a 6 inch (152mm) minimum diameter 24 gauge mild steel
black or 26 gauge blued steel, or an approved air-insulated
double wall venting pipe.
Thimble:
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet NFPA
211 Standards. Prefabricated must be suitable for use with
selected chimney and meet UL103 Type HT Standards.
Follow instructions provided by the manufacturer for
manufactured thimbles for masonry chimney and
prefabricated chimneys.
September 9, 2019
Chimney:
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements and as specified in Section 4F.
Listed Termination Cap
Roof Brace (if required)
Trim Collar on
Inside Wall
Chimney
Connector
Floor
Protector
Figure 13.1 - Prefabricated Exterior Chimney
F. Chimney Systems
Prefabricated Metal Chimney
Must be minimum 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 103 HT (2100°F) or
ULC S629M.
Must use components required by the manufacturer
for installation.
Must maintain clearances required by the manufacturer
for installation.
Refer to manufacturers instructions for installation.
NOTE: In Canada when using a factory-built chimney it
must be safety listed, Type UL103 HT (2100°F)
CLASS "A" or conforming to CAN/ULC-
S629M, STANDARD FOR 650°C FACTORY-
BUILT CHIMNEYS.
7033-350E
31M-ACC-C
Storm Collar
Flashing
Listed Chimney
Insulated " T "
Wall Support
Thimble