Page 3
Use this manual with the following models only. All 9310 models with circuit board 4403-010. IMPORTANT! The 4403 circuit board used in the model 9310 IS NOT interchangeable with the 4402 circuit board used in the earlier model 9300 operators.
Page 4
See page 36. Adjust both open and close inherent reverse sensitivity. NOTE: Operator will assume a "soft shutdown" during sensitivity adjustments. This will require operator open input to be activated to resume normal operation. See page 37. Page 4 9310-065-H-8-08...
Page 5
19. The black motor wire is routed through the donut with the number of turns shown in the table. Refer to the wire diagrams in the back of the manual. SENSITIVITY EXIT LOOP 9310-065-H-8-08 Page 5...
Page 6
ENTRAPMENT: The condition when an object is caught or held in a position that increases the risk of injury. Page 6 9310-065-H-8-08...
Inherent adjustable clutch or pressure relief device. TYPE D: Provision for connection of, or supplied with, an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. TYPE E: An inherent audio alarm. 9310-065-H-8-08 Page 7...
Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. Page 8 9310-065-H-8-08...
SAVE THESE INSTRUCTIONS! Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or www.astm.org. 9310-065-H-8-08 Page 9...
One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier. Page 10 9310-065-H-8-08...
Page 11
A wireless contact sensor shall function under the intended end-use conditions. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). 9310-065-H-8-08 Page 11...
2 ¼ inches. Install a filler or barrier in this area to reduce this gap to 2 ¼ inches or less. Install a contact sensor (type B2) on the fence to help minimize the risk of entrapment in this area. Page 12 9310-065-H-8-08...
Warning signs are to be placed on each side of the Open Loop gate so that they are easily visible from either side (Optional) of the gate. A separate pedestrian access located so pedestrians cannot come in contact with the vehicular gate. 9310-065-H-8-08 Page 13...
½ HP 115 VAC Wire Diagram ........................50 ½ HP 208/230/460 VAC Wire Diagram ....................51 1 HP 115 VAC Wire Diagram ........................52 1 HP 208/230 VAC Single Phase Wire Diagram..................53 1 HP 208/230 VAC Three Phase Wire Diagram ..................54 9310-065-H-8-08 Page 15...
Note 1: Assumes gate is in good working condition installed on a level surface. Note 2: Operators with Convenience Open Option 800 Lbs. (1/2 HP), 1300 Lbs. (1 HP) 28.5 (1 HP) 16.5 21.5 (1/2 HP) 9310-065-H-8-08 Page 17...
Concrete Pad The model 9310 vehicular gate operator is designed to be mounted on a concrete pad. 1. Construct a form for the mounting pad according to the specifications shown below. Note that the pad for the 1 HP operator extends an additional 6 inches to the right to accommodate the larger cover.
We recommend 1/2 x 2 or 3/8 x 2 sleeve anchors (not supplied). After drilling the mounting holes, clean them out and install the sleeve anchors. Position the operator over the anchors and tighten. 9310-065-H-8-08 Page 19...
6. If the operator is to be rear mounted, an endless idler assembly (P/N 2600-818) is required. Depending on the length of the gate, additional chain may also be required. See detail on page 18. Page 20 9310-065-H-8-08...
Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. 9310-065-H-8-08 Page 23...
• Use separate conduits for high and low voltage. • We suggest that minimum ¾-inch conduit be used. • Be sure that all conduits are installed in accordance with local codes. 9310-065-H-8-08 Page 25...
½ - 1 HP - 115 VAC Power ½ HP - High Voltage 3 Power 1 HP - High Voltage 3 Power 208/230/460 208/230 VAC 3 Ph VAC 3 Ph GREEN BLACK WHITE GREEN GREEN BLACK BLACK BLACK BLACK BLACK BLACK Page 26 9310-065-H-8-08...
Partial open input. Devices connected here will open the gate to 14-feet only. Reverse input functions only when gate is in the closing cycle. Must use a DoorKing 3-button control station. Others will not work. DOORKING, INC., INGLEWOOD, CA 90301 Model 9310 Title: Control and Secondary Device Wiring Date: 5/07 Dwg.
Normally Open (NO) or Normally Closed (NC) operation. Contact rating is 1 amp maximum at 24 Volts. DRY RELAY CONTACT 24 VOLT COMMON Same as terminal 1. ALARM OUTPUT ALARM RESET SOLENOID LOCK MOTOR WARNING MOTOR HIGH VOLTAGE! 115 VAC HOT 115 VAC NEUTRAL 9310-065-H-8-08 Page 31...
If an open edge sensor is activated prior to the gate reaching the full open position, the gate will stop and enter a soft shutdown condition. 5. COMMON Common terminal for the secondary entrapment protection device inputs. 6. COMMON Page 32 9310-065-H-8-08...
1 HP 208 / 3 5 See wire diagram: 1 HP 230 / 3 5 4403-1-202346-3 REVERSE SENSOR CLOSE OPEN MIN MAX MIN MAX DOORKING, INC., INGLEWOOD, CA 90301 Title: 4403 Control Board Adjustments Date: 8/08 Dwg. No. M9310-065-8 Rev. 9310-065-H-8-08 Page 33...
Changing the setting of this switch without physically changing the lock assembly will damage the operator. 2. Do not run the self-test while the gate operator is connected to the gate. This self-test feature is designed for bench-testing only. Page 34 9310-065-H-8-08...
Switch 3: Sets the circuit board to function with slide gate operators (switch OFF) or overhead gate operators (switch ON). This switch must be left in the OFF position for model 9310 Slide Gate Operator. Switch 4: This switch should be left in the OFF position when the slide gate is running on a level or small incline track and the gate does not coast.
Slide to Adjust Partial Open Limit IMPORTANT! 3-Phase Power Limit Switch Test This test MUST be performed if the 9310 is powe red from a 3-phase power source. Activate the operator and watch the limit nut movement. Manually activate the limit switch that the limit nut is movi ng towards.
1 and 4 as in step 1 to reactivate the automatic close timer. 7. You may have to repeat step 2 several times to find the correct sensitivity adjustment. 9310-065-H-8-08 Page 37...
The AC POWER toggle switch turns power to the operator ON (toggle up) or OFF (toggle down). The DC POWER toggle switch (units equipped with POWER the backup option only) turns power to the DC backup system ON (toggle up) or OFF (toggle down). 9310-065-H-8-08 Page 39...
"intended input" includes any command, any standard safety input and any loop input. Activating any of these inputs will reset the gate. At that point the gate will return to normal operation. If the gate is open, the automatic close timer will then time out and close the gate. Page 40 9310-065-H-8-08...
Activation of a close command will run the gate to the closed position. NOTE: The gate operator will not lose its limit settings when a hard shutdown occurs. 9310-065-H-8-08 Page 41...
For manual fail-safe gate operation, turn power to the operator OFF. If a backup power system is in use, be sure that this power is turned OFF also. Once power is OFF, the gate can be manually operated. Page 42 9310-065-H-8-08...
Be sure that primary (AC) and backup (DC) power is removed or shut-off prior to placing the gate operator in manual operation. Insert the manual release key into the keyed release on the side of the gate operator, and turn it clockwise 1/4 turn. The gate can now be manually operated. 1/4 TURN 9310-065-H-8-08 Page 43...
Release Check manual release for proper operation. Secondary Check that secondary (external) reverse device(s) stop or reverse Reverse Device the gate when activated. Sprockets Check set-screws for tightness. Complete Complete check of gate and gate operating system. 9310-065-H-8-08 Page 45...
If the motor runs in both steps above, replace the control board. If the motor does not run, or runs in only one direction, problem can be a bad motor, motor capacitor, wire connections from the control board to the motor or a bad control board. 9310-065-H-8-08 Page 47...
Page 48
• There may be a problem with the current sensor on the circuit board. Replace the circuit Operator runs for 1 board. second and stops, two short beeps are heard. Page 48 9310-065-H-8-08...
5.4 Accessories The following accessory items can be used with the model 9310 slide gate operator. Contact Sensor Contact sensors for use as a secondary entrapment protection device. Miller Edge, Inc. ME120, ME123, MG020, MGR20, MGS20 Photo Cell Non-contact (photo cells) sensors for use as a secondary entrapment protection device.
Convenience Outlets White Black White Black Black Operator Power Chassis Ground Black 115 VAC DOORKING, INC., INGLEWOOD, CA 90301 White Input Title: Model 9310 Wire Diagram Green ½ HP 115 VAC Date: 5/05 Dwg. No. 4403-05-115-1 Rev. Page 50 9310-065-H-8-08...
2 power legs and Black Input cap the third. Blue Green Black 460V Brown DOORKING, INC., INGLEWOOD, CA 90301 White Title: Model 9310 Wire Diagram ½ HP 208/230/460 VAC Black/White Date: 5/05 Dwg. No. 4403-05-202346 Rev. 9310-065-H-8-08 Page 51...
Convenience Outlets White Black White Black Black Operator Power Chassis Ground Black 115 VAC DOORKING, INC., INGLEWOOD, CA 90301 White Input Title: Model 9310 Wire Diagram Green 1 HP 115 VAC Date: 12/07 Dwg. No. 4403-1-115-1 Rev. Page 52 9310-065-H-8-08...
Black Blue Black 230V Brown Black 208/230 V White Black Single Phase Black/White Input Green DOORKING, INC., INGLEWOOD, CA 90301 Title: Model 9310 Wire Diagram 1 HP 208/230 VAC Single Phase Date: 12/07 Dwg. No. 4403-1-2023-1 Rev. 9310-065-H-8-08 Page 53...
208 V White Black White Black 230 V Black 208/230 V Black Three Phase Black Input Green DOORKING, INC., INGLEWOOD, CA 90301 Title: Model 9310 Wire Diagram 1 HP 208/230 VAC Three-Phase Date: 8/08 Dwg. No. 4403-1-202346-3 Rev. Page 54 9310-065-H-8-08...