  • Page 1 SC22-3 Safety Controller QuIck START GuIde...
  • Page 2 SC-XM1 External Memory Card Power Status RUN Mode I/O Fault TX/RX RUN Mode Data Transfer between PC and SC22-3 Safety Outputs Safety Output ON 1, 2, 3 The minimum height of the registered trademark symbol shall be 3/64 of Safety Output OFF an inch.
  • Page 3: Get Started

    GeT STARTed This QUICK START GUIDE will help you: • Install the SC22-3 PC Interface (PCI) software • Configure your application with the PCI • Confirm your configuration Take these items out of the kit SC22-3 Safety Controller Plug-in Terminals...
  • Page 4: Install The Software

    Insert CD into computer CD drive To install: run setup.exe, or click “Install Software” on launch menu Restart computer for maximum functionality On restart, Banner Safety Controller icon will appear on your desktop Double-click icon to launch PCI Double-click icon to launch PCI...
  • Page 5 Review the PC Interface screen Create and manage your files with the TOOL BAR TOOL BAR CONFIGURATION Configuration DOCUMENTS Summary I/O FILES Wiring Diagram Quickly review and access View finished system diagrams I/O property information and summary with the Ladder Logic with the I/O FILES CONFIGURATION DOCUMENTS Diagram...
  • Page 6 GeT SeT Name and save your configuration Click “Systems Settings” in the Tool Bar Enter configuration name and click “OK” Click “Save” to save the configuration file CAUTION! Thoroughly read the instruction manual before using this product in a safeguarding application.
  • Page 7: Add A Safety Input

    Add a safety input Click “Add Safety Input” in the Tool Bar Select a device Modify device properties: a. Select device circuit type b. Select reset logic c. Map inputs and outputs d. Click “OK” This process may be used for either safety or non-safety input devices.
  • Page 8 Set timing functions Click “Safety Outputs” in the Tool Bar Configure output properties: a. Select safety output b. Select delay type c. Specify delay time limit d. Click “OK” Establish Status Output properties Select “Status Outputs” from the Tool Bar and select any of the following: •...
  • Page 9: Get Going

    GeT GOING Confirm your configuration Power the SC22-3 Controller, and connect it to the PC via the USB cable Click “Save” to save configuration file Click “Confirm” in Tool Bar Enter Controller’s password (Default password is “0000”) Confirm each correct input or output parameter checkbox Click “OK”...
  • Page 10 Using the SC-XM1 external memory card The external memory card stores one configuration and can be used to: • Configure a replacement Controller on the factory floor • Clone other Controllers without the use of a PC • Reconfigure an in-service Controller on the factory floor without the use of a PC...
  • Page 11: System Overview

    SC22-3 Safety Controller System Overview Safety Input Devices Non-Safety Input Devices CAMERA-READY LOGOTYPE OF THE UL MARK These Marks are registered by Underwriters Laboratories Inc. E-Stops Light Curtains Two-Hand Controls Interlock Switches Manual Resets ON/OFF Switches Features: • 22 input terminals for monitoring up to 22 devices •...
  • Page 12: Specifications

    SPecIfIcATIONS (Detailed specs available in the manual) Power 24V dc +/- 20% 400 mA max (no output loads) 5.9A (all outputs ON at maximum load) Housing 35 mm DIN mount IEC IP 20 rating Plug-in terminals Inputs 22 (safety or non-safety inputs) Configurable for solid-state or contact-based input devices Safety Outputs 3 independent, dual-channel, PNP (6 terminals)
  • Page 13 (PCI) or on-board controller interface (OBI) maps each input device to any of 3 safety outputs • Configurations are confirmed before use, for assurance of safety integrity • Configurations are transferable to multiple SC22-3 Section Contents Controllers • Password protected Section 1 Overview .
  • Page 14 29 units 130 mm WARNING! For Safe Use: Although the Banner SC22-3 Safety Controller can be used in a broad set of safeguarding applications, IT IS The uSeR’S ReSPONSIbILITy TO: • Read and understand the manual • Assess what safeguarding devices and methods are appropriate for any given...