10. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
STILL
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: B, address: 41, and set data: 30.
4)
Select page: F, address: 37, and set data: 9B.
5)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button.
6)
Select page: 6, address: 01, set data: 0B, and press the PAUSE
button.
(The auto white balance standard data input is performed and
the adjustment data is stored in page: F, address: 3A to 3D,
59.)
7)
Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1)
Select page: B, address: 41, and set data: 00.
2)
Select page: 6, address: 01, and set data: 00.
3)
Select page: F, address: 37, set data: 93, and press the PAUSE
button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
11. Auto White Balance ND Filter Compensation
Adjustment
Adjust to the proper auto white balance output data with Built-in
ND filter.
If it is not correct, auto white balance and color reproducibility will
be poor.
Mode
Subject
Filter
Adjustment Page
Adjustment Address
Note 1: Perform "Auto White Balance Standard Data Input" before this
adjustment.
Note 2: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: B, address: 41, set data: 30, and press the PAUSE
button.
4)
Select page: 6, address: 1C, set data: 03, press PAUSE button
and wait for one second.
5)
Select page: F, address: 37, and set data: 9B.
6)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button.
7)
Select page: 6, address: 01, set data: 09, and press the PAUSE
button.
(The auto white balance adjustment ND filter compensation is
performed and the adjustment data is stored in page: F, address:
4F and 50.)
8)
Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1)
Select page: B, address: 41, and set data: 00.
2)
Select page: 6, address: 1C, set data: 00, and press the PAUSE
button.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: F, address: 37, set data: 93, and press the PAUSE
button.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
5-27
STILL
Clear chart
(Color reproduction adjustment frame)
Built-in ND filter
F
4F, 50