(Using Flange Back Adjustment Chart); Flange Back Check - Sony DSC-F505 Service Manual

Digital still camera
Hide thumbs Also See for DSC-F505:
Table of Contents

Advertisement

3. Flange Back Adjustment

(Using Flange Back Adjustment Chart)

The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
STILL
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 350 ± 50 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
14 to 25
Note: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: FF.
3) Check that the center of the chart for the flange back adjustment
and center of the exposure screen coincide.
4) Check that the data of page: F, address: 14 to 25 is the initial
value (See table below).
Address
Data
Address
14
1C
1A
15
94
1B
16
26
1C
17
EC
1D
18
13
1E
19
B9
1F
5) Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
6) Select page: 6, address: 01, set data: 15, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 14 to 25.)
7) Select page: 6, address: 02, and check that the data is changed
to "01".
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2) Select page: 5, address: F1, and set data: 00.
3) Select page: 0, address: 01, and set data: 00.
4) Perform "Flange Back Check".
Data
Address
Data
00
20
20
00
21
20
00
22
23
00
23
44
46
24
0A
00
25
00

4. Flange Back Check

Mode
Subject
Measurement Point
Measuring Instrument
Specified Value
Checking method:
1) Place the Siemens star 2.0m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3) Shoot the siemens star with the zoom TELE end.
4) Turn on the auto focus
5) Observe the TV monitor and check that the lens is focused.
6) Select page: 0, address: 01, and set data: 01.
7) Select page: 5, address: F1, and set data: FF.
8) Select page: 6, address: 2C, and set data: 01.
9) Shoot the siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1) Select page: 6, address: 2C, and set data: 00.
2) Select page: 5, address: F1, and set data: 00.
3) Select page: 0, address: 01, and set data: 00.
5-24
STILL
Siemens star
(2.0 m from the front of the lens)
(Luminance : approx. 200 lux)
Check operation on TV monitor
The lens is focused.