18. CCD Black Defect Compensation Check

Mode
STILL
Subject
Clear chart
(25 cm from the front of the lens)
(Note1)
Measurement Point
Display data of page: 6, address: 55
Measuring Instrument
Adjustment remote commander
Specified Value
00
Note 1: Check that there are no dust, no dirt and no reflection on the clear
chart.
Note 2: Any subject other than the clear chart should not be in the screen.
Note 3: This adjustment should be carried out upon completion of
"CCD Black Defect Compensation".
Checking method:
1)
Turn the power of the unit OFF and then ON.
2)
Wait until the camera picture appear on the screen.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: 5, address: F1, and set data: FF.
5)
Select page: F, address: DF, after noting down the data, set
data: 5A, and press PAUSE button.
6)
Select page: 6, address: 2C, and set data: 01.
7)
Select page: 6, address: 90, and set data: 00.
8)
Select page: 6, address: 91, and set data: 03.
9)
Select page: 6, address: 92, and set data: 00.
10) Select page: 6, address: 93, and set data: 00.
11) Select page: 6, address: 01, and set data: 79.
12) Select page: 6, address: 30, set data: 07, and wait for four
seconds.
13) Select page: 6, address: 01, set data: 89, and press the PAUSE
button.
14) Select page: 6, address: 02, and check that the data changes to
"01".
15) Select page: 6, address: 55, and check that the data is "00". (If
the data is other than "00", black defect compensation has
errors.)
Processing after Completing Adjustments:
1)
Select page: F, address: DF, set the data noted down at step 5),
and press the PAUSE button.
2)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 6, address: 2C, and set data: 00.
4)
Select page: 6, address: 30, and set data: 00.
5)
Select page: 6, address: 91, and set data: 00.
6)
Select page: 5, address: F1, and set data: 00.
7)
Select page: 0, address: 01, and set data: 00.
5-33