Will Burt Night Scan Chief Installation, Operation & Maintenance Manual page 45

Transportable lighting system
Table of Contents

Advertisement

Err 2,07
Err 2,08
Err 2,09
Err 2,10
Revision 1
Unrecoverable
The RCP board
Communicatio
has not sent out
n Error
communications
recently
Software Fault Internally detected
error
Tilt Up Limit
The tilt down
photosensor was
made before the
up photosensor
indicating wrap
around or the up
photosensor is
linear or defective
Tilt Down Limit The tilt up
photosensor was
made before the
down photosensor
indicating wrap
around or the
down photosensor
is linear or
defective
Night Scan Chief
Bad connection in
communications link, or
RCP is not powered or is
inadequately powered.
Make sure the power at
the RCP board is at
least 10.5 volts. Check
continuity of the internal
coiled cable between the
base board and the RCP
board (see system
schematics in section
4.4)
Indicates a software
problem. Notify Will-Burt
Check to make sure the
tilt flag is not located in
between the two
photosensors. If it is,
slowly move the left light
bank by hand (with
power off) until it is in the
proper position.
Readjustment of the flag
may be necessary to set
the proper home
position. If the flag is not
in between, replace the
RCP board
Check to make sure the
tilt flag is not located in
between the two
photosensors. If it is,
slowly move the left light
bank by hand (with
power off) until it is in the
proper position.
Readjustment of the flag
may be necessary to set
the proper home
position. If the flag is not
in between, replace the
RCP board