Err 1,13
Err 1,14
Err 1,15
Revision 1
Mast Nested
The proximity switch
Proximity Switch
sensing the mast
Disagreement
actuator at almost
nested position has
conflicting
complementary
outputs.
Mast Down
The magnetic switch
Magnetic Switch
sensing the mast is
Disagreement
lowered (referring to
tube set) has
conflicting
complementary
outputs.
Actuator 90 °
The proximity switch
sensing the mast
Proximity Switch
actuator at 90 °
Wiring Error
appears to have its
complimentary
Night Scan Chief
schematics in
section 4.4
There may be a
wiring problem, or a
defective proximity
switch. Check the
voltages at black
and white wires with
respect to the blue
wire. These two
voltages should be
opposite of each
other as the
proximity switch is
activated and
inactivated. The
voltages should be
close to battery
voltage or close to
ground. If they are
not, replace the
actuator almost
nested proximity
switch. Refer to
system schematics
in section 4.4
There may be a
wiring problem, or a
defective proximity
switch. Check the
voltages at J3 pins 5
and 7 with respect to
pin 6. These two
voltages should be
opposite of each
other as the
magnetic switch is
activated and
inactivated. The
voltages should be
close to battery
voltage or close to
ground. If they are
not, replace the
Mast Down switch.
Refer to system
schematics in
section 4.4
This check is only
made at power-up
when the mast
thinks it is nested.
The wires on pins 1
4-12