Figure 2-2 Night Scan Base Mounting Hole Locations - Will Burt Night Scan Chief Installation, Operation & Maintenance Manual

Transportable lighting system
Table of Contents

Advertisement

4.8
2.4
Junction Box Installation
The junction box serves as an interface between the Hand Held Remote Control and the Night Scan
Base. It is not used in installations where only the Panel Mount Remote Control is used. The junction
box is not rated for installation in wet locations. The installer must take necessary precautions to seal the
lid and the knockouts if installation in a wet location is unavoidable. The junction box also serves as a
location to which DC power is routed by the installer for the unit. It may be flush or surface mounted.
Hardware for mounting is not supplied.
DC \ CONTROL CABLE
Flush Mounting
For a flush mount installation, four #8 screws, nuts and lock washers must be provided by the installer.
The screw length should be 3 ½ inches plus the panel thickness. Remove the junction box cover and
make the necessary cable connections (see schematics in section 4.4). Place the junction box behind
the panel and guide the screws through the panel, junction box cover and junction box. Secure on back
side using lock washers and nuts.
Revision 1
SADDLE MOUNTING
HOLES ( n .56" SEE NOTE)
5.5
Figure 2-2
Night Scan Base Mounting Hole Locations
CORD GRIP FOR
TO NIGHT SCAN
HOLES PROVIDED
FOR OPTIONAL
FLUSH MOUNTING
Figure 2-3
BASE MOUNTING
HOLES ( n .56" SEE NOTE)
40 1/8" (6FT. MAST)
46 1/8" (7.5FT. MAST)
KNOCK-
OUT
HHRC CONNECTOR
Standard Junction Box
Night Scan Chief
33.0
11.0
JUNCTION BOX
ENCLOSURE
PUSH
PULL
SW ITCH
2-3