Err 1,07
Err 1,08
Err 1,09
Err 1,10
Err 1,11
Err 1,12
Revision 1
Unrecoverable
The Base board has
Communication
not sent out
Error
communications
recently
Software Fault
Internally detected
error
Initiate
The Initiate input has
Pushbutton
been closed for too
long.
EEPROM Life
More than 20,000
writes have been
made to a particular
EPROM location
Saddle Location
The internal linear
actuator limit switch
has opened before
preload occurred
Actuator 90 °
The proximity switch
sensing the mast
Proximity Switch
actuator at 90 ° has
Disagreement
conflicting
complementary
outputs.
Night Scan Chief
mast path, and
confirm that the
proximity switch is
being properly
activated.
Indicates a software
problem. Notify Will-
Burt
Indicates a software
problem. Notify Will-
Burt
Wiring Short in the
DC cable or
incorrect DIP switch
setting (S2)
Will only occur when
the mast has had in
excess of 20,000
cycles which is
unlikely to happen.
Replace the base
board.
The saddle is too
low with respect to
the Chief base. Shim
the saddle up as
needed. Refer to
section 2.4 for
flatness
requirement.
There may be a
wiring problem, or a
defective proximity
switch. Check the
voltages at J3 pins 1
and 3 with respect to
pin 2. These two
voltages should be
opposite of each
other as the
proximity switch is
activated and
inactivated. The
voltages should be
close to battery
voltage or close to
ground. If they are
not, replace the
actuator 90 °
proximity switch.
Refer to system