Vacuum Pump Connections; Computer/Monitor Installation - X-Rite Set Up And Operation Manual

Automated color management scanning system
Hide thumbs Also See for x-rite:
Table of Contents

Advertisement

®
I N T E L L I T R A X

Vacuum Pump Connections

1. Connect one end of the vacuum hose (1) to the barbed input fitting located on the
vacuum pump, and the other end to the barbed fitting on the side of the docking station.
2. Plug one end of the vacuum cable (2) into the connecter on the control box (3) and the
other end into the connector on the back of the docking station.
3. Make sure the voltage selection switch (4) on the top of the control box (3) is set to the
proper line voltage for your region.
4. Connect the detachable line cord (5) to the control box (3), and then plug the line cord
into an easily accessible, grounded AC wall receptacle (6).
NOTE: To obtain 15% more vacuum from the pump, remove the exhaust barbed
adapter (7).
Vacuum Cable (2)
Vacuum Hose (1)

Computer/Monitor Installation

If the system you purchased included a computer and monitor, refer to the documentation
that is included with those products for specific installation procedures.
6
A U T O S C A N N I N G
Control Box (3)
S Y S T E M
To AC Wall
Receptacle (6)
Line Cord (5)
Voltage Selection
Switch (4)
Exhaust Barbed Adapter (7)