Cleaning The Filter; Filter Counter Reset - Eiki LC-XAU200 Owner's Manual

Multimedia projector
Hide thumbs Also See for LC-XAU200:
Table of Contents

Advertisement

Cleaning the filter

The air filter prevents dust from accumulating on the surface of the optical elements inside
the projector. Should the air filter become clogged with dust particles, it will reduce cooling
fans' effectiveness and may result in a buildup of internal heat and adversely affects the life of
the projector. If the Filter warning icon appears on the screen, the air filter should be cleaned
immediately. Clean the air filter following the steps below.
1 Turn off the projector, and unplug the AC
power cord from the AC outlet.
2 Remove the air filter.
3 Gently clean the filter with a brush.
4 Reinstall the filter into the projector properly.
Caution
Do not operate the projector with the air filter
removed. Dust may accumulate on the
optical elements, degrading picture quality.
Do not put any small objects into the air
intake vents. Otherwise, it may result in
malfunction of the projector.
ORDER REPLACEMENT FILTER
Replacement Filter can be ordered through your
dealer. When ordering a filter, give the following
information to the dealer.
Replacement Filter P/N:63340020

Filter counter reset

Be sure to reset the filter counter after cleaning
or replacing the filter.
1. Press Menu on the remote control to display
the screen menu. Press to select
Expand, then press OK button.
2. Press  to select Filter, and then press
OK button.
Press  to select Filter counter reset and
press OK button, "Filter counter Reset?"
appears on screen, select "Yes" to continue.
3. When another dialog box pops up, select
"Yes" to reset the filter.
Maintenance and cleaning
Filter
Recommendation
We recommend avoiding dusty/smoky
environments when you operate the projector.
Usage in these environments may cause poor
image quality.
When you use the projector under dusty or
smoky conditions, dust may accumulate on the
lens, LCD panels, or optical elements inside
the projector. When the symptoms above are
noticed, contact your authorized dealer or
service center for proper cleaning.
Filter counter
PC adjust
Filter counter
Timer
Display
Filter counter reset
Color adjust
Setting
Expand
Info.
Move
Yes
No
Move
Select
Yes
OK?
Yes
No
Move
Select
Filter counter
0 H
400 H
Next
Back
Filter counter Reset?
appears.
Select Yes, then
another confirmation
Back
box appears.
Select Yes again
to reset the Filter
counter.
Back
55