Section B : Specifications; Special Features; Safety Features - Monitor M2200 Owner's Manual

Heating systems
Table of Contents

Advertisement

SECTION B
SPECIFICATIONS
Model
Monitor 2200
Fuel Type
Red dyed or Clear Kerosene or Low Sulphur *1 Oil
Heater Efficiency
93%*
Heat Rating
High:22,000 BTU/hour
H.Medium: 17,400 BTU/hour
L.Medium: 12,400 BTU/hour
Low:9,600 BTU/hour
Heater Output
High: 18,260 BTU/hour
H.Medium: 14,440 BTU/hour
L.Medium: 10,290 BTU/hour
Low:7,970BTU/hour
Fuel Tank
Separate(Capsule tank optional)
Fuel Consumption
High:0.164 Gallon/hour
H.Medium:0.13 Gallon/hour
L.Medium:0.09 Gallon/hour
Low:0.07 Gallon/hour
Power Source
120 Volts AC; 60 Hz
Power Consumption
Ignition: 250 Watts
Operational Watts (Average)
Heated Air Delivery
High: 176 Cubic feet/minute
H.Medium: 176 Cubic feet/minute
L.Medium: 126 Cubic feet/minute
Low: 113 Cubic feet/minute
Vent Pipe Hole
2>2-inches Diameter
Dimensions
Weight
Height:26.0 inches
Width:20.9 inches
Depth: 13.0 inches
55 Pounds,empty
* When considering heat of condensation is lost, then the net efficiency is 88%, A.F.U.E. is 84%
SPECIAL FEATURES
AUTOMATIC IGNITION
MEMORY BACK UP:Set memory can be kept in case
of power failure for up to 30 minutes.
DUAL BLOWERS:Separate fans for combustion and
room air circulation.
THERMOSTATICALLY CONTROLLED : Adjusts to the
desired room temperature.
BUILT-IN TIMER: Heater will automatically operate as
programmed by the user.
AUTOMATIC RESET AFTER POWER FAILURE:Heater
will automatically resume operation after power
is restored.
INDICATOR LIGHTS: Easy-to-see signals show when
heater is in operation, when timer is activated, and
when the burner is operating.
CHOICE OF FUEL SUPPLY: Separate tank or Capsule
tank optional.
MULTIPLE HEAT EXCHANGER: Extracts 88% of heat
from burner.
CLEAN OPERATION: Products of combustion are vented
outside.
CONSUMES NO ROOM AIR: Air for combustion is drawn
from outside.
EASY INSTALLATION: Includes all parts required for
standard installation.
SAFETY FEATURES
SAFE RE-LIGHTING:Heater will not restart until its
combustion chamber has cooled.
ELECTRICAL PROTECTION: Heater automatically shuts
off in the unlikely event of a malfunction in the
electrical circuitry or disruption of the power supply.
NO EXHAUST IN ROOM : Products of combustion are
discharged outdoors.
FLUE PIPE: Outside air is drawn through a pipe-within-
a-pipe venting system. This process
preheats
combustion air and regains heat from exhaust
gases.
£± CAUTION:ALTERNATE POWER SOURCES
The Monitor 2200 may not operate when powered
by sources such as an auxiliary generator, UPS
(Uninterruptedpower Source), inverters, etc.Check
with
your
dealer for
guidance on
specific
applications.