NOTE:
The "STANDARD" damper is to be used with
extension kits up to 1 bend (90° elbow) with
extension kit total length of 0-73 in. or up to 2 bends
(90°elbows) with extension kit total length of 0-38 in.
or up to 3 bends (90 ° elbows) with no extension.
The "EXTENSION"
damper
must
be
used
installations that exceed any of the limits above.
Step15 : Recheck the Heater
Before proceeding, check again to be sure there are
no flammable materials close to the heater. Check to
be sure the heater is level.
Examine the flue pipe to be sure connections are tight.
Step13 : Install the Flue Pipe Holder
Place the ring of the flue pipe holder around the flue
pipe. The other side of the holder hooks in a slot
directly above the joint pipe at the rear of the heater
(see Figure 20).
Flue Pipe Holder
Fig. 20
Step14 : Secure the Heater
Insert the narrow ends of the body clamp into sockets
on the rear of the heater.
Install the adjustment screws and extend the clamp
until they touch the wall. Fasten the clamp to the
wall with 1 # SxXtapping screw.
NOTE: If use of body clamp is not feasible or
practical, the heater should be secured by
screws to floor through punched holes in spill
tray.