OPTIONAL CAPSULE TANK INSTALLATION
Optional capsule tank kit is available from your Monitor
dealer.
/h CAUTION: The conversion of the Monitor 2200 for use
of the capsule can present a Risk of Electrical Shock.
The necessary Electrical and Fuel piping work that
MUST be done ONLY by an authorized Servicing Dealer.
Step 1 :
Be sure the nut at the rear lower side of the heater is
secured (See Figure 24).
Step 2 :
Remove the screws at the Front Cover Assy, and carefully
remove the Front Cover Assy (See Figure 25).
Nipple
Nut
Fig. 24
Front Cover Assy.
Fig. 25
Step 3 : Disconnect the plugs of the RED and BROWN wires marked "U" attached to the printed wiring board to
enable the Fuel Empty Float Switch (See Figure 26).
Printed Wiring Board
Lead Wires
I—="•
Color: Red/Brown
Marking : "U"
Plug For Open Circuit
Fig. 26