Accessories You May Need; Flue Pipe Extensions - Monitor M2200 Owner's Manual

Heating systems
Table of Contents

Advertisement

ACCESSORIES YOU MAY NEED
Check the list below and see your MPI dealer for accessories you may need or want for installation of your heating-
system.
A\ CAUTION: Only use the flue pipe supplied with the Monitor 2200, or the approved accessory kits available from
your Monitor or dealer.
ACCESSORY
Medium Adjustable Flue Pipe Kit
Long Adjustable Flue Pipe Kit
Lifter Pump
Extra Short, Short, Medium or
P/N 8051
P/N 8052
P/N 1101
APPLICATION
For use where wall thickness is up to 12 /^ inches
For use where wall thickness is up to 20 inches
For use with large capacity tank where gravity feed is not
practical
For use where "standard" installation is not practical
Long Extension Kit or Elbow Adapter Kit
(See Flue Pipe Extensions, page 7)
Fitting and Tank
For large capacity fueling: To be dealer installed
EXTENSION KIT LENGTH
Extra Short Extension Kit
Short Extension Kit
Medium Extension Kit
Long Extension Kit
P/N 82 12
P/N 8004
P/N 8003
P/N 8002
7'/6 to 1 1 !/2 inches (18.2 to 29.2cm)
1 1 1/2 to 2014 inches (29.2 to 51 .4cm)
20'/4 to 38 inches (51 .4 to 96.5cm)
38 to 73 inches (96.5 to 185.4cm)
FLUE PIPE EXTENSIONS
Four standard extension kits are available from your
Monitor dealer. Most installations can be made with
one of these kits. In special cases, custom installations
may be required. These may be made with components
purchased from your dealer.
In any installation the following limitations MUST NOT
BE EXCEEDED:
1. The total length of the intake or exhaust pipe should
not exceed 10 feet (3m) with 3 elbows, 13 feet (4m)
with 2 elbows, or 16 1/2 feet (5m) with 1 elbow.
2. These elbows should include the one used at the
heater but not the one on the air supply hose nor the
integral bends in the flue pipe. (See Figure 2)
3. The correct damper as shown on Page 13 must be
used.