SPECIFICATIONS
Model No.
GF 3800
Type of Appliance
Fan type direct vent wall furnace
Input Rating
Nat. Gas 38,000 BTU/hour
LP. Gas 34,500 BTU/hour
Output Rating
Nat. Gas 30,700 BTU/hour
LP. Gas 27,900 BTU/hour
Efficiency
83%
Electrical Rating
120V, 60Hz, Less than 2 amperes
Power Consumption
80 Watts
Heated Air Delivery
High
388 Cubic feet/minute
Low
300 Cubic feet/minute
Flue Pipe Hole
2.5 inches diameter
Dimensions
Height: 26.6 inches (67.56cm)
Width: 28.7 inches (72.90cm)
Depth: 14.0 inches (35.50 cm)
Weight
82 pounds
Inlet Gas Supply Pressure
Nat. Gas Max. 10.5 inch W.C. (267 mmHzO)
Min.
5.1 inch W.C. (130 mmHaO)
LP. Gas Max. 13.0 inch W.C. (330 mmHzO)
Min.
11.0 inch W.C. (279 mmH
2
O)
Manifold Test Pressure
Nat. Gas
3.4 inch W.C. (86 mmHzO)
LP. Gas
3.!5inch W.C. (80mmH2O)
The minimum and maximum inlet gas supply pressure are for the purpose of input adjustment.
The efficiency rating of this appliance is a product of thermal efficiency rating determined under
continuous operating conditions and was determined independently of any installed system.
SPECIAL FEATURES
AUTOMATIC IGNITION
MEMORY BACK UP: Set memory can be kept in case of
power failure for up to30minutes.
DUAL BLOWERS: Separate fans for combustion and
room air circulation.
THERMOSTATICALLY CONTROLLED: Adjusts to the
desired room temperature.
BUILT-IN TIMER: Heater will automatically operate as
programmed by the user.
AUTOMATIC RESET AFTER POWER FAILURE: Heater
will automatically resume operation after power is
restored.
INDICATOR LIGHTS: Easy-to-see signals show when
heater is in operation, when timer is activated, and
when the burner is operating.
CLEAN OPERATION: Products of combustion are vented
outside.
CONSUMES NO ROOM AIR: Air for combustion is drawn
from outside.
EASY INSTALLATION: Includes all parts required for
standard installation.
SAFETY FEATURES
SAFE RE-LIGHTING: Heater will not restart until its
combustion chamber has cooled.
ELECTRICAL PROTECTION: Heater automatically shuts
off in the unlikely event of a malfunction in the electrical
circuitry or disruption of the power supply.
NO EXHAUST IN ROOM: Products of combustion are
discharged outdoors.
FLUE PIPE: Outside air is drawn through a pipe-within-
a-pipe venting system. This process preheats
combustion air and regains heat from exhaust gases.
/|\ CAUTION: ALTERNATE POWER SOURCES
The Monitor GF3800 may not operate when powered
by sources such as an auxiliary generator, UPS
(Uninterrupted Power Source), inverters, etc.
Check with your dealer for guidance on specific
applications.

Hide quick links: