2-2-22. KSW-55 Board, HN-361 Board
1. Refer to Sections from 2-2-3 to 2-2-5 and
disassemble the unit up to "Handle Assem-
bly" removal.
2. Remove the rubber SW key.
3. Disconnect the harnesses and AXM-42 board
from the connectors (CN2, CN3, CN5, CN6,
CN7) on the KSW-55 board.
4. Remove the four screws, and remove the
KSW-55 board.
5. Disconnect the control switch block from the
connector (CN4) on the KSW-55 board.
6. Disconnect the HN-361 board from the
connector (CN1) on the KSW-55 board.
7. Reinstall the KSW-55 board and HN-361
board by reversing the steps of removal.
PMW-EX1R
M 2 x 3
(silver)
CN5
CN7
CN2
CN3
CN1
KSW-55 board
Rubber SW key
KSW-55 board
CN6
Control switch block
AXM-42 board
CN4
Control switch block
HN-361 board
2-21 (E)